OPERATION PANELS A-57
5-12
Rapid Traverse Rate Override Switches [RAPID OVERRIDE]
The RAPID OVERRIDE switches are used to adjust rapid
traverse rate.
For example, these switches are used when a tool is
moved at a rapid traverse rate in test cutting.
During test cutting, although positioning is specified at a
rapid traverse rate, positioning must
be executed at a
relatively slow feedrate to ensure safe operation. The
switches are used in such a case to lower axis feedrate
when executing positioning while checking axis feed
operation.
Switch operation is impossible with the PANEL
key-switch placed in the
(OFF) position.
The rapid traverse rate is adjusted in three steps;
(fine feed), 25%, and 100% (set rapid
traverse rate).
1.
When the power is turned on,
(fine feed) is selected to ensure safety.
2.
For manual operation, the maximum allowable override value is 50%. Therefore, if
the
(100%) switch is pressed, the override value is 50%.
3.
The rapid traverse override function is valid in the dry run mode.
4.
When the operation mode is changed from automatic to manual,
(fine feed) is
selected to ensure safety.
25%
100%
RAPID OVERRIDE
NOTE
NOTE
100%