DOOR INTERLOCK FUNCTION P-21
<Manual and automatic operation (door interlock function released)>
The following table shows the permitted and prohibited operations if the DOOR INTERLOCK key-
switch is placed in the
RELEASE
position while the machine door is open.
*1
Some of specifications and options may not be featured on your machine,
depending on the model and specifications.
*2
Automatic operation is possible only while the single block function is valid or MDI
mode is selected.
*3
Rapid traverse rate for rapid traverse operation and that in zero return operation are
clamped at 5 m/min. For jog and manual pulse generator feed operation, no such
restriction is provided.
If the DOOR INTERLOCK key-switch is placed in the
RELEASE
position while the machine door is open, automatic operation is
permitted conditionally.
In manual operations, there are no restrictions with an exception that
rapid traverse rate for axis movement is clamped at a certain value.
Status
Door Opened
DOOR INTERLOCK
key-switch:
RELEASE
Automatic
operation
Robot fence door open
Possible under certain conditions
*2
Robot fence door close
Possible under certain conditions
*2
Manual
operation
Rotation of spindle
(rotary tool spindle
*1
)
Possible
Jogging of spindle
(rotary tool spindle
*1
)
Possible
Turret indexing
Possible
Axis feed
Possible under certain conditions
*3
Coolant supply
Possible
Chip conveyor
*1
Possible
C-axis selection
*1
Possible
Spindle gear range change
*1
Possible
DOOR INTERLOCK
NORMAL
RELEASE
NOTE