Parameters
(C) Motor constant parameters
FR-A800
5 - 467
For the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
For the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
Changing the motor constant (if setting motor constants in the internal data of the inverter)
●
Set Pr. 71 as follows.
First
motor Pr.
Second
motor Pr.
Name
Setting range
Setting
increments
Initial value
82
455
Motor excitation current
(No-load current)
0 to 500 A, 9999
0.01 A
9999
0 to 3600 A, 9999
0.1 A
90
458
Motor constant (R1)
0 to 50 Ω, 9999
0.001 Ω
0 to 400 mΩ, 9999
0.01 mΩ
91
459
Motor constant (R2)
0 to 50 Ω, 9999
0.001 Ω
0 to 400 mΩ, 9999
0.01 mΩ
92
460
Motor constant (L1)/d-axis
inductance (Ld)
0 to 6000 mH, 9999
0.1 mH
0 to 400 mH, 9999
0.01 mH
93
461
Motor constant (L2)/q-axis
inductance (Lq)
0 to 6000 mH, 9999
0.1 mH
0 to 400 mH, 9999
0.01 mH
94
462
Motor constant (X)
0 to 100%, 9999
0.1%
0.01%
859
860
Torque current/Rated PM motor
current
0 to 500 A, 9999
0.01A
0 to 3600 A, 9999
0.1 A
298
560
Frequency search gain
0 to 32767, 9999
1
Tab. 5-185:
Parameter setting ranges
NOTE
If "9999" is set, tuning data will be invalid and the constant values for Mitsubishi motors (SF-PR,
SF-JR, SF-HR, SF-JRCA, SF-HRCA and SF-V5RU (1500 r/min series) and so on) are used.
Motor
Pr. 71 setting
Mitsubishi standard motor
Mitsubishi high-efficiency motor
SF-JR and SF-TH
3 (4)
SF-JR 4P 1.5 kW or lower
23 (24)
SF-HR
43 (44)
Others
3 (4)
Mitsubishi constant-torque motor
SF-JRCA 4P
SF-TH (constant-torque)
13 (14)
SF-HRCA
53 (54)
Other (SF-JRC, etc.)
13 (14)
Mitsubishi high-performance energy-
saving motor
SF-PR
73 (74)
Vector control dedicated motor
SF-V5RU (1500 r/min series)
SF-THY
33 (34)
SF-V5RU (other than the 1500 r/min series)
13 (14)
Other manufacturer's standard motor
⎯
3 (4)
Other manufacturer's constant-torque
motor
⎯
13 (14)
Tab. 5-186:
Motor selection
Summary of Contents for FR-A820-00046 (0.4K)
Page 2: ......
Page 4: ......
Page 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Page 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Page 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1190: ...EC Declarations of Conformity Appendix A 50 ...
Page 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Page 1192: ...EC Declarations of Conformity Appendix A 52 ...
Page 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1194: ...EC Declarations of Conformity Appendix A 54 ...
Page 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1196: ...EC Declarations of Conformity Appendix A 56 ...
Page 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Page 1198: ...EC Declarations of Conformity Appendix A 58 ...
Page 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Page 1200: ...EC Declarations of Conformity Appendix A 60 ...
Page 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Page 1202: ...EC Declarations of Conformity Appendix A 62 ...
Page 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Page 1204: ...EC Declarations of Conformity Appendix A 64 ...
Page 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Page 1206: ...EC Declarations of Conformity Appendix A 66 ...
Page 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Page 1208: ...EC Declarations of Conformity Appendix A 68 ...
Page 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Page 1210: ...EC Declarations of Conformity Appendix A 70 ...
Page 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Page 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Page 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Page 1214: ...EC Declarations of Conformity Appendix A 74 ...
Page 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Page 1217: ......