Parameters
Control method
FR-A800
5 - 73
Keeping the motor speed constant when the load fluctuates (speed control gain)
●
Use Pr. 89 to keep the motor speed constant during variable load operation.
(This parameter is useful to make adjustments on the motor speed after replacing a conventional
model with an FR-A800 series model.)
NOTES
To perform driving in a better accuracy, perform offline auto tuning, then set the online auto tun-
ing, and select Real sensorless vector control.
Under this control, rotations are more likely to be uneven than under V/F control. (This control
method is not suitable for grinder, wrapping machine, etc., which require even rotation at a low
speed.)
For FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower, the operation with a surge
voltage suppression filter (FR-ASF-H/FR-BMF-H) installed between the inverter and the motor may
reduce the output torque.
The optional sine wave filter (MT-BSL/BSC) cannot be used between the inverter and the motor.
Changing the terminal assignment using Pr. 178 to Pr. 189 (input terminal function selection) may
affect the other functions. Set parameters after confirming the function of each terminal.
Pr.
Name
Initial
value
Setting
range
Description
89
G932
Speed control gain
(Advanced magnetic flux
vector)
9999
0 to 200%
Makes adjustments to keep the motor speed
constant during variable load operation under
Advanced magnetic flux vector control.
The reference value is 100%.
9999
The gain set by Pr. 71. (The gain set in accordance
with the motor.)
569
G942
Second motor speed
control gain
9999
0 to 200%
Makes adjustments to keep the second motor speed
constant during variable load operation under
Advanced magnetic flux vector control.
The reference value is 100%.
9999
The gain set by Pr. 450. (The gain set in accordance
with the motor.)
Fig. 5-7:
Adjusting speed fluctuations
I002504E
Lo
a
d
t
o
rq
u
e
Speed
Summary of Contents for FR-A820-00046 (0.4K)
Page 2: ......
Page 4: ......
Page 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Page 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Page 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1190: ...EC Declarations of Conformity Appendix A 50 ...
Page 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Page 1192: ...EC Declarations of Conformity Appendix A 52 ...
Page 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1194: ...EC Declarations of Conformity Appendix A 54 ...
Page 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1196: ...EC Declarations of Conformity Appendix A 56 ...
Page 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Page 1198: ...EC Declarations of Conformity Appendix A 58 ...
Page 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Page 1200: ...EC Declarations of Conformity Appendix A 60 ...
Page 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Page 1202: ...EC Declarations of Conformity Appendix A 62 ...
Page 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Page 1204: ...EC Declarations of Conformity Appendix A 64 ...
Page 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Page 1206: ...EC Declarations of Conformity Appendix A 66 ...
Page 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Page 1208: ...EC Declarations of Conformity Appendix A 68 ...
Page 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Page 1210: ...EC Declarations of Conformity Appendix A 70 ...
Page 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Page 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Page 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Page 1214: ...EC Declarations of Conformity Appendix A 74 ...
Page 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Page 1217: ......