Parameters
(N) Operation via communication and its settings
FR-A800
5 - 679
Keepalive time (Pr. 1455)
An alive check message (KeepAlive ACK) is sent to a device if the device does not return any response
within the time set in Pr. 1455 "Keepalive time" while a TCP connection is established. When no re-
sponse is returned after the third transmission, the connection will be forced to be closed.
Ethernet IP filtering function (Pr. 1442 to Pr. 1448)
●
Set the IP address range for connectable network devices (Pr. 1442 to Pr. 1448) to limit the
connectable devices. The IP address setting range depends on the settings in Pr. 1443 and Pr. 1446,
Pr. 1444 and Pr. 1447, and Pr. 1445 and Pr. 1448.
(Either of the settings can be larger than the other in Pr. 1443 and Pr. 1446, Pr. 1444 and Pr. 1447,
and Pr. 1445 and Pr. 1448.)
m
I003109E
Fig. 5-330:
Process of Keepalive checking
Example
Setting example 1:
In this case, the IP address range in which Ethernet communication is permitted is "192.168.x (1 to
3).xxx (100 to 150)".
I003110A
Fig. 5-331:
Ethernet IP filtering function setting example 1
Connected device
Normal communication
KeepAlive ACK (first)
KeepAlive ACK (second)
Inverter
Time
KeepAlive ACK (third)
Timeout (connection close)
Time set in
Pr. 1455
Time set in
Pr. 1455
Time set in
Pr. 1455
Time set in
Pr. 1455
No response
No response
No response
192
168
1
100
―
9999
3
150
192
168
1
100
ʊ
9999
3
150
Pr. 1442
Ethernet IP address for
filtering
The range is between the
values set in both
parameters.
Pr. 1443
Pr. 1444
Pr. 1445
Pr. 1446
Pr. 1447
Pr. 1448
Filtering range setting for
the Ethernet IP address
The range is between the
values set in both
parameters.
Summary of Contents for FR-A820-00046 (0.4K)
Page 2: ......
Page 4: ......
Page 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Page 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Page 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1190: ...EC Declarations of Conformity Appendix A 50 ...
Page 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Page 1192: ...EC Declarations of Conformity Appendix A 52 ...
Page 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1194: ...EC Declarations of Conformity Appendix A 54 ...
Page 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1196: ...EC Declarations of Conformity Appendix A 56 ...
Page 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Page 1198: ...EC Declarations of Conformity Appendix A 58 ...
Page 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Page 1200: ...EC Declarations of Conformity Appendix A 60 ...
Page 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Page 1202: ...EC Declarations of Conformity Appendix A 62 ...
Page 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Page 1204: ...EC Declarations of Conformity Appendix A 64 ...
Page 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Page 1206: ...EC Declarations of Conformity Appendix A 66 ...
Page 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Page 1208: ...EC Declarations of Conformity Appendix A 68 ...
Page 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Page 1210: ...EC Declarations of Conformity Appendix A 70 ...
Page 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Page 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Page 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Page 1214: ...EC Declarations of Conformity Appendix A 74 ...
Page 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Page 1217: ......