Parameters
(E) Environment setting parameters
FR-A800
5 - 205
5.7.6 Display-off
mode
The LED of the operation panel (FR-DU08) can be turned OFF when it has not been operated for a cer-
tain period of time.
●
If the operation panel has not been operated for the time set in Pr. 1048, the display-off mode is
enabled and its LED is turned OFF.
●
In the display-off mode, the "MON" LED flickers slowly.
●
The count to display off is reset at installation/removal of the operation panel, power-ON/OFF of
the inverter, or inverter reset.
●
Display-off mode end condition
–
Operation of the operation panel
–
Occurrence of a warning, alarm, or fault
–
Installation/removal of the operation panel, power-ON/OFF of the inverter, or inverter reset
–
Connection/disconnection of the USB A connector
5.7.7
Resetting USB host errors
When a USB device is connected to the USB connector (connector A), the USB host error can be can-
celed without performing an inverter reset.
●
Parameter copy (refer to page 5-740) and the trace function (refer to page 5-610) can be used
when a USB device (such as a USB memory) is connected to the USB connector (connector A).
●
When a device such as a USB charger is connected to the USB connector and an excessive current
(500 mA or higher) flows, USB host error
(UF warning) is displayed on the operation panel.
●
If a UF warning occurs, disconnect the USB device and set Pr. 1049 = "1" to cancel the USB error.
(The UF warning can also be canceled by resetting the inverter power or resetting with the RES
signal.)
Pr.
Name
Initial value
Setting range
Description
1048
E106
Display-off waiting time
0
0
Display-off mode disabled
1 to 60 min
Set time until the LED of the
operation panel is turned OFF.
NOTE
The "P.RUN" LED is on in the display-off mode (when the PLC function is operating).
Pr.
Name
Initial value
Setting range
Description
1049
E110
USB host reset
0
0
Read only
1
Resets the USB host.
Summary of Contents for FR-A820-00046 (0.4K)
Page 2: ......
Page 4: ......
Page 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Page 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Page 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1190: ...EC Declarations of Conformity Appendix A 50 ...
Page 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Page 1192: ...EC Declarations of Conformity Appendix A 52 ...
Page 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1194: ...EC Declarations of Conformity Appendix A 54 ...
Page 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1196: ...EC Declarations of Conformity Appendix A 56 ...
Page 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Page 1198: ...EC Declarations of Conformity Appendix A 58 ...
Page 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Page 1200: ...EC Declarations of Conformity Appendix A 60 ...
Page 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Page 1202: ...EC Declarations of Conformity Appendix A 62 ...
Page 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Page 1204: ...EC Declarations of Conformity Appendix A 64 ...
Page 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Page 1206: ...EC Declarations of Conformity Appendix A 66 ...
Page 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Page 1208: ...EC Declarations of Conformity Appendix A 68 ...
Page 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Page 1210: ...EC Declarations of Conformity Appendix A 70 ...
Page 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Page 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Page 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Page 1214: ...EC Declarations of Conformity Appendix A 74 ...
Page 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Page 1217: ......