(E) Environment setting parameters
Parameters
5 - 210
Initial values differ depending on the rating as follows.
The rated current and motor capacity differ depending on the inverter capacity. Refer to the
inverter rated specifications (page 8-1).
The initial value for FR-A820-00077(0.75K) or lower and FR-A840-00038(0.75K) or lower, is set to
85% of the inverter rated current.
●
Setting Pr. 292 "Automatic acceleration/deceleration" = "5 or 6 (lift mode)" will change the stall
prevention operation level as shown below.
Pr.
P
r. 570
set
ti
ng
200 V class FR-A820-
첸
00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 01540 01870 02330 03160 03800 04750
(0.4K) (0.75K) (1.5K) (2.2K) (3.7K) (5.5K) (7.5K) (11K)
(15K) (18.5K) (22K)
(30K)
(37K)
(45K)
(55K)
(75K)
(90K)
400 V class FR-A840-
첸
00023 00038 00052 00083 00126 00170 00250 00310 00380 00470 00620 00770 00930 01160 01800 02160 02600
(0.4K) (0.75K) (1.5K) (2.2K) (3.7K)s (5.5K) (7.5K) (11K)
(15K) (18.5K) (22K)
(30K)
(37K) s(45K) (55K)
(75K)
(90K)
or
higher
0 [%]
0, 1
6
4
4
4
3
3
2
2
2
2
2
2
1.5
1.5
1
1
1
2
6
6
4
4
4
3
3
2
2
2
2
2
2
2
2
1
1
3
6
6
6
4
4
4
3
3
2
2
2
2
2
2
2
2
1
7 [s]
0, 1
5
5
5
5
5
5
15
15
15
15
15
15
15
15
15
15
15
2
5
5
5
5
5
5
5
15
15
15
15
15
15
15
15
15
15
3
5
5
5
5
5
5
5
5
15
15
15
15
15
15
15
15
15
8 [s]
0, 1
10
10
10
10
10
10
30
30
30
30
30
30
30
30
30
30
30
2
5
5
5
5
5
5
5
15
15
15
15
15
15
15
15
15
15
3
5
5
5
5
5
5
5
5
15
15
15
15
15
15
15
15
15
12
[%]
0, 1
4
4
4
4
4
4
2
2
2
2
2
2
2
2
1
1
1
2
4
4
4
4
4
4
4
2
2
2
2
2
2
2
2
1
1
3
4
4
4
4
4
4
4
4
2
2
2
2
2
2
2
2
1
Tab. 5-74:
Initial values of Pr. 0, Pr. 7, Pr. 8 and Pr. 12 depending on Pr. 570 setting
Pr.
Setting
Pr. 570 setting
Refer to
page
0
1
2 (Initial value)
3
292
5
110%
120%
150%
200%
6
115%
140%
180%
230%
Tab. 5-75:
Influence of Pr. 292 on the stall prevention operation level
NOTES
When Pr. 570 = "0" (SLD rating), carrier frequency automatic reduction is enabled regardless of the
setting in Pr. 260 "PWM frequency automatic switchover".
To use the FR-A820-03160(55K) and FR-A840-01800(55K) in the LD and SLD ratings, a DC reactor,
which is available as an option, corresponding to the applied motor is required.
Setting the LD or SLD rating to the FR-A820-03160(55K) and FR-A840-01800(55K) changes their
parameter setting increments and setting ranges in the same way as for the FR-A820-03800(75K)
and FR-A840-02160(75K) or higher. For example, the setting increment and the setting range of
Pr. 9 will change from "0.01 A" to "0.1 A" and from "0 to 500 A" to "0 to 3600 A". For the setting of
each parameter, refer to the parameter list (on page 5-2).
Parameters referred to
Pr. 260
PWM frequency automatic switchover
=>
Summary of Contents for FR-A820-00046 (0.4K)
Page 2: ......
Page 4: ......
Page 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Page 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Page 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1190: ...EC Declarations of Conformity Appendix A 50 ...
Page 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Page 1192: ...EC Declarations of Conformity Appendix A 52 ...
Page 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1194: ...EC Declarations of Conformity Appendix A 54 ...
Page 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1196: ...EC Declarations of Conformity Appendix A 56 ...
Page 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Page 1198: ...EC Declarations of Conformity Appendix A 58 ...
Page 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Page 1200: ...EC Declarations of Conformity Appendix A 60 ...
Page 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Page 1202: ...EC Declarations of Conformity Appendix A 62 ...
Page 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Page 1204: ...EC Declarations of Conformity Appendix A 64 ...
Page 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Page 1206: ...EC Declarations of Conformity Appendix A 66 ...
Page 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Page 1208: ...EC Declarations of Conformity Appendix A 68 ...
Page 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Page 1210: ...EC Declarations of Conformity Appendix A 70 ...
Page 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Page 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Page 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Page 1214: ...EC Declarations of Conformity Appendix A 74 ...
Page 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Page 1217: ......