(A) Application parameters
FR-A800
5 - 535
Description of orientation operation (Vector control)
●
Setting the rotation direction (Pr. 393 "Orientation selection")
Orientation from the current rotation direction (Pr. 393 = "0 (initial value)", 10) (Vector control)
●
When the orientation command (X22) is input, the motor speed will decelerate from the running
speed to Pr. 351 "Orientation speed." At the same time, the orientation stop position command
will be read in. (The stop position command is determined by the setting of Pr. 350 "Stop position
command selection" and Pr. 360 "16-bit data selection". Refer to the chart below.)
●
When the orientation switchover speed is reached, the encoder Z phase pulse will be confirmed,
and the control will change from speed control to position control (Pr. 362 "Orientation position
loop gain").
●
The distance to the orientation stop position is calculated at switching of the control, and the
motor decelerates to a stop with a set deceleration pattern (Pr. 399 "Orientation deceleration
ratio") and enters the orientation (servo lock) state.
●
Once in the Pr. 357 "Orientation in-position zone", the orientation complete (ORA) signal is output.
●
The home position can be moved using Pr. 361 "Position shift".
Pr. 393 setting
Rotation direction
Remarks
0
(initial value)
Pre-orientation
Orientation is executed from the current rotation
direction.
Motor end
orientation
1
Forward rotation
orientation
Orientation is executed from the forward rotation
direction.
(If the motor is running in reverse, orientation is
executed from the forward rotation direction after
deceleration.)
2
Reverse rotation
orientation
Orientation is executed from the reverse rotation
direction.
(If the motor is running forward, orientation is
executed from the reverse rotation direction after
deceleration.)
10
Pre-orientation
Orientation is executed from the current rotation
direction.
Machine end
orientation
11
Forward rotation
orientation
Orientation is executed from the forward rotation
direction.
(If the motor is running in reverse, orientation is
executed from the forward rotation direction after
deceleration.)
12
Reverse rotation
orientation
Orientation is executed from the reverse rotation
direction.
(If the motor is running forward, orientation is
executed from the reverse rotation direction after
deceleration.)
Tab. 5-221:
Setting of parameter 393
Fig. 5-254:
Orientation from the current rotation direction
I001583E, I001584E
Speed
(forward
rotation)
ON
ON
OFF
OFF
Speed
(reverse
rotation)
X22
ORA
ON
ON
OFF
OFF
X22
ORA
Time
Time
Summary of Contents for FR-A820-00046 (0.4K)
Page 2: ......
Page 4: ......
Page 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Page 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Page 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1190: ...EC Declarations of Conformity Appendix A 50 ...
Page 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Page 1192: ...EC Declarations of Conformity Appendix A 52 ...
Page 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1194: ...EC Declarations of Conformity Appendix A 54 ...
Page 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1196: ...EC Declarations of Conformity Appendix A 56 ...
Page 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Page 1198: ...EC Declarations of Conformity Appendix A 58 ...
Page 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Page 1200: ...EC Declarations of Conformity Appendix A 60 ...
Page 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Page 1202: ...EC Declarations of Conformity Appendix A 62 ...
Page 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Page 1204: ...EC Declarations of Conformity Appendix A 64 ...
Page 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Page 1206: ...EC Declarations of Conformity Appendix A 66 ...
Page 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Page 1208: ...EC Declarations of Conformity Appendix A 68 ...
Page 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Page 1210: ...EC Declarations of Conformity Appendix A 70 ...
Page 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Page 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Page 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Page 1214: ...EC Declarations of Conformity Appendix A 74 ...
Page 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Page 1217: ......