Parameters
(M) Monitor display and monitor output signal
FR-A800
5 - 361
Frequency monitor reference (Pr. 55)
●
Set the full-scale value for outputting the monitored items of output frequency, frequency setting
value, and Dancer main speed setting to the terminals FM, CA and AM.
●
For the FM-type inverters, set the full-scale value of the connected meter when the pulse speed
of terminal FM is 1440 pulses/s (50k pulses/s). Set the frequency to be indicated as the full scale
value on the frequency meter (1 mA analog meter) connected between terminal FM and SD. (For
example, 60 Hz or 120 Hz.) Pulse speed is proportional to the output frequency of the inverter.
(Maximum pulse train output is 2400 pulses/s (55k pulses/s).)
●
For the CA-type inverters, set the full-scale value of the connected meter when output current of
terminal CA is 20 mA. Set the frequency to be indicated as the full scale value on the meter (20 mA
DC ammeter connected between terminal CA and 5; for example, 60 Hz or 120 Hz. Output current
is proportional to the frequency. (The maximum output current is 20 mA DC.)
●
For the calibration of terminal AM, set the full-scale value of the connected meter when output
voltage of terminal FM is 10 V DC. Set the frequency to be indicated as the full scale value on the
meter (10 V DC voltmeter) connected between terminal AM and 5. (For example, 60 Hz or 120 Hz)
Output voltage is proportional to the frequency. (The maximum output voltage is 10 V DC.)
FM type: 60 Hz; CA type: 50 Hz
Output with a negative sign available when Pr. 290 "Monitor negative output selection" = "1, 3"
Fig. 5-155:
Frequency monitoring reference for terminal FM
I002608E
Fig. 5-156:
Frequency monitoring reference for terminal CA
I002609E
Fig. 5-157:
Frequency monitoring reference for terminal AM
I002610E
Output frequency
Setting range of Pr. 55
60 Hz
(initial value)
P
ulse sp
eed (pulses/s)
1 Hz
400 Hz
2400
(55k)
1440
(50k)
Output Current
DC 20 mA
50 Hz
(initial value)
120 Hz
Setting range of Pr. 55
∗2
∗1
Setting range of Pr. 55
60 Hz
(initial value)
120 Hz
10 V DC
Output voltage
60 Hz
10 V DC
Summary of Contents for FR-A820-00046 (0.4K)
Page 2: ......
Page 4: ......
Page 144: ...System configuration for Ethernet communication FR A800 E Installation and wiring 2 114 ...
Page 202: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 1090: ...Check first when you have a trouble Protective functions 6 50 ...
Page 1189: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1190: ...EC Declarations of Conformity Appendix A 50 ...
Page 1191: ...Appendix EC Declarations of Conformity FR A800 A 51 ...
Page 1192: ...EC Declarations of Conformity Appendix A 52 ...
Page 1193: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1194: ...EC Declarations of Conformity Appendix A 54 ...
Page 1195: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1196: ...EC Declarations of Conformity Appendix A 56 ...
Page 1197: ...Appendix EC Declarations of Conformity FR A800 A 57 ...
Page 1198: ...EC Declarations of Conformity Appendix A 58 ...
Page 1199: ...Appendix EC Declarations of Conformity FR A800 A 59 ...
Page 1200: ...EC Declarations of Conformity Appendix A 60 ...
Page 1201: ...Appendix EC Declarations of Conformity FR A800 A 61 ...
Page 1202: ...EC Declarations of Conformity Appendix A 62 ...
Page 1203: ...Appendix EC Declarations of Conformity FR A800 A 63 ...
Page 1204: ...EC Declarations of Conformity Appendix A 64 ...
Page 1205: ...Appendix EC Declarations of Conformity FR A800 A 65 ...
Page 1206: ...EC Declarations of Conformity Appendix A 66 ...
Page 1207: ...Appendix EC Declarations of Conformity FR A800 A 67 ...
Page 1208: ...EC Declarations of Conformity Appendix A 68 ...
Page 1209: ...Appendix EC Declarations of Conformity FR A800 A 69 ...
Page 1210: ...EC Declarations of Conformity Appendix A 70 ...
Page 1211: ...Appendix EC Declarations of Conformity FR A800 A 71 ...
Page 1212: ...EC Declarations of Conformity Appendix A 72 A 7 2 FR A846 series ...
Page 1213: ...Appendix EC Declarations of Conformity FR A800 A 73 ...
Page 1214: ...EC Declarations of Conformity Appendix A 74 ...
Page 1215: ...Appendix EC Declarations of Conformity FR A800 A 75 ...
Page 1217: ......