PARAMETER
PARAMETER
—
126 Terminal 4 frequency setting gain frequency 0 to 400Hz
0.01Hz
60Hz
126
1A
9A
1
{
{
{
{
×
{
{
{
×
{
PI
D
127
PID control automatic switchover frequency 0 to 400Hz, 9999
0.01Hz
9999
127
1B
9B
1
{
{
{
×
×
{
×
{
{
{
128
PID action selection
10, 11, 20, 21, 50, 51, 60, 61
1
10
128
1C
9C
1
{
{
{
×
×
{
×
{
{
{
129
PID proportional band
0.1 to 1000%, 9999
0.1%
100%
129
1D
9D
1
{
{
{
×
×
{
×
{
{
{
130
PID integral time
0.1 to 3600s, 9999
0.1s
1s
130
1E
9E
1
{
{
{
×
×
{
×
{
{
{
131
PID upper limit
0 to 100%, 9999
0.1%
9999
131
1F
9F
1
{
{
{
×
×
{
×
{
{
{
132
PID lower limit
0 to 100%, 9999
0.1%
9999
132
20
A0
1
{
{
{
×
×
{
×
{
{
{
133
PID action set point
0 to 100%, 9999
0.01%
9999
133
21
A1
1
{
{
{
×
×
{
×
{
{
{
134
PID differential time
0.01 to 10.00s, 9999
0.01s
9999
134
22
A2
1
{
{
{
×
×
{
×
{
{
{
Elect
ronic byp
a
ss
135
Electronic bypass sequence selection
0, 1
1
0
135
23
A3
1
{
{
{
×
×
{
×
{
{
{
136
MC switchover interlock time
0 to 100s
0.1s
1s
136
24
A4
1
{
{
{
×
×
{
×
{
{
{
137
Start waiting time
0 to 100s
0.1s
0.5s
137
25
A5
1
{
{
{
×
×
{
×
{
{
{
138
Bypass selection at a fault
0, 1
1
0
138
26
A6
1
{
{
{
×
×
{
×
{
{
{
139
Automatic switchover frequency from
inverter to bypass operation
0 to 60Hz, 9999
0.01Hz
9999
139
27
A7
1
{
{
{
×
×
{
×
{
{
{
Ba
ck
la
sh
m
easure
s
140
Backlash acceleration stopping frequency 0 to 400Hz
0.01Hz
1Hz
140
28
A8
1
{
{
{
{
×
{
{
{
{
{
141
Backlash acceleration stopping time
0 to 360s
0.1s
0.5s
141
29
A9
1
{
{
{
{
×
{
{
{
{
{
142
Backlash deceleration stopping frequency 0 to 400Hz
0.01Hz
1Hz
142
2A
AA
1
{
{
{
{
×
{
{
{
{
{
143
Backlash deceleration stopping time
0 to 360s
0.1s
0.5s
143
2B
AB
1
{
{
{
{
×
{
{
{
{
{
—
144
Speed setting switchover
0, 2, 4, 6, 8, 10, 102, 104,
106, 108, 110
1
4
144
2C
AC
1
{
{
{
{
{
{
{
{
{
{
PU
145
PU display language selection
0 to 7
1
0
145
2D
AD
1
{
{
{
{
{
{
{
{
×
×
Current
det
ect
io
n
148
Stall prevention level at 0V input
0 to 220%
0.1%
150%
148
30
B0
1
{
{
×
×
×
×
×
{
{
{
149
Stall prevention level at 10V input
0 to 220%
0.1%
200%
149
31
B1
1
{
{
×
×
×
×
×
{
{
{
150
Output current detection level
0 to 220%
0.1%
150%
150
32
B2
1
{
{
{
{
{
{
{
{
{
{
151
Output current detection signal delay time 0 to 10s
0.1s
0s
151
33
B3
1
{
{
{
{
{
{
{
{
{
{
152
Zero current detection level
0 to 220%
0.1%
5%
152
34
B4
1
{
{
{
{
{
{
{
{
{
{
153
Zero current detection time
0 to 1s
0.01s
0.5s
153
35
B5
1
{
{
{
{
{
{
{
{
{
{
—
154
Voltage reduction selection during stall
prevention operation
0, 1
1
1
154
36
B6
1
{
{
×
×
×
×
×
{
{
{
—
155
RT signal function validity condition
selection
0, 10
1
0
155
37
B7
1
{
{
{
×
×
{
×
{
{
{
—
156
Stall prevention operation selection
0 to 31, 100, 101
1
0
156
38
B8
1
{
{
×
×
×
×
×
{
{
{
—
157
OL signal output timer
0 to 25s, 9999
0.1s
0s
157
39
B9
1
{
{
{
{
{
{
{
{
{
{
—
158
AM terminal function selection
1 to 3, 5 to 14, 17, 18, 21, 24,
32 to 34, 50, 52, 53
1
1
158
3A
BA
1
{
{
{
{
{
{
{
{
{
{
—
159
Automatic switchover frequency range from
bypass to inverter operation
0 to 10Hz, 9999
0.01Hz
9999
159
3B
BB
1
{
{
{
×
×
{
×
{
{
{
—
160 User group read selection
0, 1, 9999
1
0
160
00
80
2
{
{
{
{
{
{
{
{
{
{
—
161
Frequency setting/key lock operation
selection
0, 1, 10, 11
1
0
161
01
81
2
{
{
{
{
{
{
{
{
×
{
A
u
to
m
a
tic
r
e
st
a
rt
162
Automatic restart after instantaneous power
failure selection
0, 1, 2, 10, 11, 12
1
0
162
02
82
2
{
{
{
{
×
{
{
{
{
{
163
First cushion time for restart
0 to 20s
0.1s
0s
163
03
83
2
{
{
×
×
×
×
×
{
{
{
164
First cushion voltage for restart
0 to 100%
0.1%
0%
164
04
84
2
{
{
×
×
×
×
×
{
{
{
165
Stall prevention operation level for restart
0 to 220%
0.1%
150%
165
05
85
2
{
{
×
×
×
×
×
{
{
{
Current
d
e
te
ct
io
n
166
Output current detection signal retention
time
0 to 10s, 9999
0.1s
0.1s
166
06
86
2
{
{
{
{
{
{
{
{
{
{
167
Output current detection operation
selection
0, 1
1
0
167
07
87
2
{
{
{
{
{
{
{
{
{
{
—
168
Parameter for manufacturer setting. Do not set.
168
Parameter for manufacturer setting. Do not set.
—
169
169
Cu
m
u
la
tiv
e
m
o
n
ito
r
cl
ear
170
Watt-hour meter clear
0, 10, 9999
1
9999
170
0A
8A
2
{
{
{
{
{
{
{
{
×
{
171
Operation hour meter clear
0, 9999
1
9999
171
0B
8B
2
{
{
{
{
{
{
{
×
×
×
Fu
nct
io
n
[Pr.]
Name
Setting Range
Minimum Setting
Increments
Initial Value
Refer to
Page
[Pr.]
Option
Instruction Code
Control Mode-based Correspondence Table
P
ar
a
me
te
r
Cop
y
P
ar
a
me
te
r
Cle
a
r
All P
ara
me
te
r
Cle
a
r
Re
ad
Wr
it
e
E
xt
ende
d
V/F
con
tr
o
l
Advanced
magnetic
flux
vector
control
Vector control
Real sensorless
vector control
S
p
eed
co
nt
ro
l
To
rque
co
nt
ro
l
Po
sit
ion
co
nt
ro
l
Speed
control
Torque
control
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...