198
198
PARAMETER
PARAMETER
PA
R
A
M
E
T
E
R
2
PI
D oper
at
ion
575
Output interruption detection time
0 to 3600s, 9999
0.1s
1s
575
4B
CB
5
{
{
{
{
{
576
Output interruption detection level
0 to 400Hz
0.01Hz
0Hz
576
4C
CC
5
{
{
{
{
{
577
Output interruption cancel level
900 to 1100%
0.1%
1000%
577
4D
CD
5
{
{
{
{
{
-
611
Acceleration time at a restart
0 to 3600s, 9999
0.1s
9999
611
0B
8B
6
{
{
{
{
{
-
653
Speed smoothing control
0 to 200%
0.1%
0
653
35
B5
6
{
{
{
{
{
-
665
Regeneration avoidance frequency gain
0 to 200%
0.1%
100
665
41
C1
6
{
{
{
{
{
P
rot
ect
iv
e
funct
ions
872
Input phase loss protection selection
0, 1
1
0
872
48
C8
8
{
{
{
{
{
Regener
at
ion av
oi
d
ance
func
tion
882
Regeneration avoidance operation
selection
0, 1, 2
1
0
882
52
D2
8
{
{
{
{
{
883
Regeneration avoidance operation level
300 to 800V
0.1V
780VDC
883
53
D3
8
{
{
{
{
{
885
Regeneration avoidance compensation
frequency limit value
0 to 10Hz, 9999
0.01Hz
6Hz
885
55
D5
8
{
{
{
{
{
886
Regeneration avoidance voltage gain
0 to 200%
0.1%
100%
886
56
D6
8
{
{
{
{
{
Fr
e
e
pa
ra
m
e
te
r
888
Free parameter 1
0 to 9999
1
9999
888
58
D8
8
{
{
{
×
×
889
Free parameter 2
0 to 9999
1
9999
889
59
D9
8
{
{
{
×
×
-
891
Cumulative power monitor digit shifted
times
0 to 4, 9999
1
9999
891
5B
DB
8
{
{
{
{
{
Calibrat
ion p
a
ram
e
te
rs
C0
(900)
FM terminal calibration
-
-
-
C0
(900)
5C
DC
1
{
{
{
×
{
C2
(902)
Terminal 2 frequency setting bias
frequency
0 to 400Hz
0.01Hz
0Hz
C2
(902)
5E
DE
1
{
{
{
×
{
C3
(902)
Terminal 2 frequency setting bias
0 to 300%
0.1%
0%
C3
(902)
5E
DE
1
{
{
{
×
{
125
(903)
Terminal 2 frequency setting gain
frequency
0 to 400Hz
0.01Hz
60Hz
125
(903)
5F
DF
1
{
{
{
×
{
C4
(903)
Terminal 2 frequency setting gain
0 to 300%
0.1%
100%
C4
(903)
5F
DF
1
{
{
{
×
{
C5
(904)
Terminal 4 frequency setting bias
frequency
0 to 400Hz
0.01Hz
0Hz
C5
(904)
60
E0
1
{
{
{
×
{
C6
(904)
Terminal 4 frequency setting bias
0 to 300%
0.1%
20%
C6
(904)
60
E0
1
{
{
{
×
{
126
(905)
Terminal 4 frequency setting gain
frequency
0 to 400Hz
0.01Hz
60Hz
126
(905)
61
E1
1
{
{
{
×
{
C7
(905)
Terminal 4 frequency setting gain
0 to 300%
0.1%
100%
C7
(905)
61
E1
1
{
{
{
×
{
C22
(922)
Frequency setting voltage bias frequency
(built-in potentiometer)
0 to 400Hz
0.01Hz
0
C22
(922)
16
96
9
{
{
{
×
{
C23
(922)
Frequency setting voltage bias (built-in
potentiometer)
0 to 300%
0.1%
0
C23
(922)
16
96
9
{
{
{
×
{
C24
(923)
Frequency setting voltage gain frequency
(built-in potentiometer)
0 to 400Hz
0.01Hz
60Hz
C24
(923)
17
97
9
{
{
{
×
{
C25
(923)
Frequency setting voltage gain (built-in
potentiometer)
0 to 300%
0.1%
100%
C25
(923)
17
97
9
{
{
{
×
{
PU
990
PU buzzer control
0, 1
1
1
990
5A
DA
9
{
{
{
{
{
991
PU contrast adjustment
0 to 63
1
58
991
5B
DB
9
{
{
{
×
{
Func
ti
on
[Pr.]
Name
Setting Range
Minimum Setting
Increments
Initial Value
Refer to
Page
[Pr.]
Instruction Code
Control Mode-based
Correspondence Table
P
ara
met
e
r
Copy
P
ara
met
e
r
Cl
e
ar
A
ll P
a
ra
m
ete
r
Cl
e
ar
Re
a
d
Wri
te
Ext
en
d
ed
V/F control
General-purpose
magnetic-flux
vector control
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...