176
PA
R
A
M
E
T
E
R
2
176
PARAMETER
PARAMETER
O
u
tput
t
e
rm
inal
f
u
nct
ion assignm
ent
190
RUN terminal function selection
0, 1, 3, 4, 7, 8, 11 to 16, 20,
25, 26, 46, 47, 64, 90, 91,
93, 95, 96, 98, 99,
100, 101, 103, 104, 107,
108, 111 to 116, 120, 125,
126, 146, 147, 164, 190,
191, 193, 195, 196, 198,
199, 9999
1
0
190
1E
9E
2
{
{
{
{
×
{
191
FU terminal function selection
1
4
191
1F
9F
2
{
{
{
{
×
{
192
A,B,C terminal function selection
0, 1, 3, 4, 7, 8, 11 to 16, 20,
25, 26, 46, 47, 64, 90, 91,
95, 96, 98, 99, 100, 101,
103, 104, 107, 108, 111 to
116, 120, 125, 126, 146,
147, 164, 190, 191, 195,
196, 198, 199, 9999
1
99
192
20
A0
2
{
{
{
{
×
{
Mult
i-s
peed s
e
tt
ing
232
Multi-speed setting (speed 8)
0 to 400Hz, 9999
0.01Hz
9999
232
28
A8
2
{
{
{
{
{
{
233
Multi-speed setting (speed 9)
0 to 400Hz, 9999
0.01Hz
9999
233
29
A9
2
{
{
{
{
{
{
234
Multi-speed setting (speed 10)
0 to 400Hz, 9999
0.01Hz
9999
234
2A
AA
2
{
{
{
{
{
{
235
Multi-speed setting (speed 11)
0 to 400Hz, 9999
0.01Hz
9999
235
2B
AB
2
{
{
{
{
{
{
236
Multi-speed setting (speed 12)
0 to 400Hz, 9999
0.01Hz
9999
236
2C
AC
2
{
{
{
{
{
{
237
Multi-speed setting (speed 13)
0 to 400Hz, 9999
0.01Hz
9999
237
2D
AD
2
{
{
{
{
{
{
238
Multi-speed setting (speed 14)
0 to 400Hz, 9999
0.01Hz
9999
238
2E
AE
2
{
{
{
{
{
{
239
Multi-speed setting (speed 15)
0 to 400Hz, 9999
0.01Hz
9999
239
2F
AF
2
{
{
{
{
{
{
-
240
Soft-PWM operation selection
0, 1
1
1
240
30
B0
2
{
{
{
{
{
{
-
241
Analog input display unit switchover
0, 1
1
0
241
31
B1
2
{
{
{
{
{
{
-
244
Cooling fan operation selection
0, 1
1
1
244
34
B4
2
{
{
{
{
{
{
S
lip
com
pensat
io
n
245
Rated slip
0 to 50%, 9999
0.01%
9999
245
35
B5
2
{
×
{
{
{
{
246
Slip compensation time constant
0.01 to 10s
0.01s
0.5s
246
36
B6
2
{
×
{
{
{
{
247
Constant-power range slip compensation
selection
0, 9999
1
9999
247
37
B7
2
{
×
{
{
{
{
-
249
Earth (ground) fault detection at start
0, 1
1
0
249
39
B9
2
{
{
{
{
{
{
-
250
Stop selection
0 to 100s, 1000 to 1100s,
8888, 9999
0.1s
9999
250
3A
BA
2
{
{
{
{
{
{
-
251
Output phase loss protection selection
0, 1
1
1
251
3B
BB
2
{
{
{
{
{
{
Lif
e
diagnosis
255
Life alarm status display
(0 to 15)
1
0
255
3F
BF
2
{
{
{
×
×
×
256
Inrush current limit circuit life display
(0 to 100%)
1%
100%
256
40
C0
2
{
{
{
×
×
×
257
Control circuit capacitor life display
(0 to 100%)
1%
100%
257
41
C1
2
{
{
{
×
×
×
258
Main circuit capacitor life display
(0 to 100%)
1%
100%
258
42
C2
2
{
{
{
×
×
×
259
Main circuit capacitor life measuring
0, 1 (2, 3, 8, 9)
1
0
259
43
C3
2
{
{
{
{
{
{
P
o
wer f
a
ilure
st
op
261
Power failure stop selection
0, 1, 2
1
0
261
45
C5
2
{
{
{
{
{
{
-
267
Terminal 4 input selection
0, 1, 2
1
0
267
4B
CB
2
{
{
{
{
×
{
-
268
Monitor decimal digits selection
0, 1, 9999
1
9999
268
4C
CC
2
{
{
{
{
{
{
-
269
Parameter for manufacturer setting. Do not set.
269
Parameter for manufacturer setting. Do not set.
-
270
Stop-on contact control selection
0, 1
1
0
270
4E
CE
2
×
{
{
{
{
{
F
unc
ti
on
[Pr.]
Name
Setting Range
Minimum Setting
Increments
Initial Value
Refer to
Page
[Pr.]
Option
Instruction Code
Control Mode-based Correspondence
Table
P
ara
met
er
Co
py
P
ara
met
er
Cle
a
r
Al
l P
ara
met
e
r
Cle
a
r
Re
ad
Wr
it
e
E
xt
e
nde
d
V/F control
Advanced
magnetic
flux vector
control
General-
purpose
magnetic-
flux vector
control