387
PARAMETER
2
P
ARAM
ETE
R
parameters not registered in the user group can not
be read.)
To register a parameter to the user group, set its
parameter number in [
Pr. 173
]. To delete a parameter
in the user group, set its parameter number in [
Pr.
174
]
. Set [
Pr. 172
= 9999] to batch delete parameters
registered.
[
Pr. 77, Pr. 160 and Pr. 991
]
can always be read,
independently of the user group setting.
[
Pr. 77, Pr. 160, Pr. 172 to Pr. 174
] cannot be registered
to the user group.
When [
Pr. 173, Pr. 174
] is read, 9999 is always
displayed.
When any value other than 9999 is set in [
Pr. 172
], no
function is available.
2.18.5 Password function [Pr. 296, 297]
Registering 4-digit password can restrict parameter reading/writing.
(1) Parameter reading/writing restriction level
[
Pr. 296
]
Level of reading/writing restriction by PU/NET mode
operation command can be selected by [
Pr. 296
].
*1
If the parameter reading is restricted by the [
Pr. 160
]
setting, those parameters are unavailable for reading
even when "
{
" is indicated.
*2
If the parameter writing is restricted by the [
Pr. 77
] setting,
those parameters are unavailable for writing even when
"
{
" is indicated.
*3
Parameter access from unit where parameter is written in
PU operation mode (initially set to operation panel,
parameter unit) is restricted. (
Refer to page 436
for PU
mode operation command source selection)
*4
Parameter access in NET operation mode with RS-485
communication is restricted.
(2) Password lock/unlock [
Pr.296, Pr.297
]
1) Lock
Set parameter reading/writing restriction level by
Pr. 296
. ([
Pr. 296
≠
9999])
When the setting is "101 to 106", the number of
password unlock errors (0 to 5 times) is displayed
when [
Pr. 297
] is read.
(When the [
Pr. 296
] setting is "1 to 6", the number
is not displayed.
Write four-digit number (1000 to 9998) in [
Pr.297
]
as a password.
(When [
Pr. 296
="9999"],
Pr.297
cannot be written.)
Once password is registered, parameter reading/
writing is restricted with the restriction level set in
[
Pr. 296
] until password unlock.
After registering a password, a read value of [
Pr.
297
] is always "0" to "5". When a password
restricted parameter is read/written,
is
displayed. Even if a password is registered,
parameters which the inverter itself writes, such
as inverter parts life, are overwritten occasionally.
Even if a password is registered, [
Pr. 991
PU
contrast adjustment
] can be read/written when a
parameter unit (FR-PU04/FR-PU07) is connected.
D700
[Pr. ]
Name
Initial Value
Setting Range
Description
296
Password lock level
9999
1 to 6, 101 to 106
Select restriction level of parameter reading/
writing when a password is registered.
9999
No password lock
297
Password lock/unlock
9999
1000 to 9998
Register a 4-digit password
(0 to 5)
Displays password unlock error count. (Reading
only)
(Valid when
Pr. 296
= "101" to "106")
(9999)
No password lock (Reading only)
[
Pr. 296
]
Setting
PU Mode Operation
Command
NET Mode
Operation
Command
Read
Write
Read
Write
9999
{
{
{
{
1, 101
{
×
{
×
2, 102
{
×
{
{
3, 103
{
{
{
×
4, 104
×
×
×
×
5, 105
×
×
{
{
6, 106
{
{
×
×
{
: enabled,
×
: disabled