349
PARAMETER
2
P
ARAM
ETE
R
Motor thermal
load ratio
0.1%
61
61
Thermal operation
level (100%)
Displays the motor thermal
integrated value (Motor overload
shuts off (E.THM) occurs at 100%)
—
—
{
{
Inverter thermal
load ratio
*12
0.1%
62
62
Thermal operation
level (100%)
Displays the transistor thermal heat
integrated value. (Inverter overload
trip (E.THT) occurs at 100%.)
—
—
{
{
PTC thermistor
resistance
0.01k
Ω
64
×
—
Displays the PTC thermistor
resistance input value to terminal 2
when PTC thermistor protection is
valid.
(0.10k
Ω
to 31.5k
Ω
)
(Refer to page 50)
—
—
—
{
*1
Frequency setting to output terminal status on the PU main monitor are selected by "other monitor selection" of the parameter
unit (FR-PU04V/FR-PU07).
*2
Position pulse and orientation status function when used with an option (FR-A7AP). If a value is set without using an option,
the display remains 0.
*3
Feedback pulse functions when the option (FR-A7AP) is used and vector control is performed.
*4
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and
accumulated again from 0. When the operation panel (FR-DU07) is used, the time is displayed up to 65.53 (65530h) on the
assumption that 1h = 0.001, and thereafter, it is added up from 0.
*5
The actual operation time is not added up if the cumulative operation time before power supply-off is less than 1h.
*6
When using the parameter unit (FR-PU04/FR-PU07), kW is displayed.
*7
The setting depends on the inverter capacity. (55K or less/75K or more)
*8
Since the panel display of the operation panel (FR-DU07) is 4 digits in length, the monitor value of more than 9999 is displayed
as ----.
*9
By setting [
Pr. 52
= 0], the monitoring of output frequency to alarm display can be selected in sequence by
.
*10 The monitor set in [
Pr. 52
] is displayed in the third monitor position. (The output voltage monitor is changed.) Note that load meter,
motor exciting current, motor load factor are displayed in the second monitor position (output current monitor).
*11 Bigger value between motor thermal and transistor thermal integrated value is displayed.
*12 A value other than 0% may be displayed if surrounding air temperature (fin temperature) is high even during a stop in
.
*13 Select torque command when using motor rating torque as a reference.
Select torque current command when using motor rating torque current as a reference.
*14 When outputting from terminal DA1 of the built-in option FR-A7AZ (when [
Pr. 838
] is set), + (plus) output at forward rotation and -
(minus) output is at reverse rotation.
*15 When outputting from terminal DA1 of the built-in option FR-A7AZ (when [
Pr. 838
] is set), + (plus) voltage is at forward rotation drive /
reverse regeneration, and - (minus) voltage is made at reverse drive/ forward regeneration.
*16 When outputting from terminal DA1 of the built-in option FR-A7AZ (when [
Pr. 838
] is set), + (plus) voltage is made at forward / reverse
drive, and - (minus) voltage is at forward/ reverse regeneration.
*17 Torque monitor can be set only to [
Pr. 838
].
Types of
Monitor
Increments
[Pr. 52] Setting
[Pr. 54]
(FM)
[Pr. 158]
(AM)
[Pr. 306]
[Pr. 310]
[Pr. 838]
Setting
Full-scale Value
Description
Available Inverters
DU
(Operation
panel)
LED
PU
main
monitor
A700
F700
E700
D700
•
Power-ON monitor (first monitor)
•
S
econd monitor
•
Third monitor
•
Fault monitor
With alarm
Output current monitor
Output voltage monitor
Output frequency monitor
•
Power-ON monitor (first monitor)
•
S
econd monitor
•
Third monitor
•
Fault monitor
With alarm
Output current monitor
Output frequency monitor
Cumulative energization time monitor
Example: When [
Pr. 52
= 20] (cumulative energization time), the monitor is displayed on the operation panel as described below.
E700 D700