![Mitsubishi Electric FR-A700 Series Technical Manual Download Page 92](http://html.mh-extra.com/html/mitsubishi-electric/fr-a700-series/fr-a700-series_technical-manual_239199092.webp)
85
1
S
PECIFI
C
A
T
IONS
SPECIFICATIONS
1.4.31 USB connector
(A700)(E700)
Connect the inverter and PC with USB cable and use FR
Configurator to make the inverter setup easily.
When using USB communication, set [
Pr. 551 PU mode
operation command source selection
= 3].
Parameter setting and monitoring are performed using FR
Configurator. Refer to the instruction manual of FR
Configurator for details.
It is recommended to fit a ferrite core to the USB cable to
reduce the effect of noises from the inverter.
USB communication specifications
A700 E700
[Pr. ]
Name
Initial
Value
Setting
Range
Description
547
USB communication
station number
0
0 to 31
Specifies the inverter station number.
548
USB communication check
time interval
9999
0
USB communication is enabled. However, the inverter will
come to an alarm stop (E. USB) if operation is changed to PU
operation mode.
0.1 to 999.8s
Set the interval of communication check time.
If a no-communication state persists for longer than the
permissible time, the inverter will come to trip (E.USB).
9999
No communication check
Interface
Conforms to USB1.1
Transmission Speed: 12Mbps
Wiring length
Maximum 5m
Connector
USB B connector (B receptacle)
USB mini B connector
(receptacle mini B type)
Power supply
Self-power supply
A700
E700
(1)
(2)
A700
E700
USB cable
USB connector
Place a flat-blade screwdriver,
etc. in a slot and push up the
cover to open.
Removal of cover
<How to open the USB connector cover>
Pull the cover in the direction of arrow.Then turn it upward.
USB
cable
USB
connector
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...