174
PA
R
A
M
E
T
E
R
2
174
PARAMETER
PARAMETER
-
146
Built-in potentiometer switching
0, 1
1
1
146
2E
AE
1
{
{
{
{
×
×
-
147
Acceleration/deceleration time switching
frequency
0 to 400Hz, 9999
0.01Hz
9999
147
2F
AF
1
{
{
{
{
{
{
Current
det
ec
tion
150
Output current detection level
0 to 200%
0.1%
150%
150
32
B2
1
{
{
{
{
{
{
151
Output current detection signal delay time 0 to 10s
0.1s
0s
151
33
B3
1
{
{
{
{
{
{
152
Zero current detection level
0 to 200%
0.1%
5%
152
34
B4
1
{
{
{
{
{
{
153
Zero current detection time
0 to 1s
0.01s
0.5s
153
35
B5
1
{
{
{
{
{
{
-
156
Stall prevention operation selection
0 to 31, 100, 101
1
0
156
38
B8
1
{
{
{
{
{
{
-
157
OL signal output timer
0 to 25s, 9999
0.1s
0s
157
39
B9
1
{
{
{
{
{
{
-
160 User group read selection
0, 1, 9999
1
0
160
00
80
2
{
{
{
{
{
{
-
161
Frequency setting/key lock operation
selection
0, 1, 10, 11
1
0
161
01
81
2
{
{
{
{
×
{
A
u
to
m
a
tic
r
e
st
a
rt
funct
ions
162
Automatic restart after instantaneous
power failure selection
0, 1, 10, 11
1
1
162
02
82
2
{
{
{
{
{
{
165
Stall prevention operation level for restart
0 to 200%
0.1%
150%
165
05
85
2
{
{
{
{
{
{
-
168
Parameter for manufacturer setting. Do not set.
168
Parameter for manufacturer setting. Do not set.
-
169
169
Cu
m
u
la
tiv
e
m
onit
o
r clear
170
Watt-hour meter clear
0, 10, 9999
1
9999
170
0A
8A
2
{
{
{
{
×
{
171
Operation hour meter clear
0, 9999
1
9999
171
0B
8B
2
{
{
{
×
×
×
Us
er
group
172
User group registered display/batch clear
9999, (0 to 16)
1
0
172
0C
8C
2
{
{
{
{
×
×
173
User group registration
0 to 999, 9999
1
9999
173
0D
8D
2
{
{
{
×
×
×
174
User group clear
0 to 999, 9999
1
9999
174
0E
8E
2
{
{
{
×
×
×
Input
t
e
rm
inal f
unct
ion as
signment
178
STF terminal function selection
0 to 5, 7, 8, 10, 12, 14 to 16,
18, 24, 25, 60, 62, 65 to 67,
9999
1
60
178
12
92
2
{
{
{
{
×
{
179
STR terminal function selection
0 to 5, 7, 8, 10, 12, 14 to 16,
18, 24, 25, 61, 62, 65 to 67,
9999
1
61
179
13
93
2
{
{
{
{
×
{
180
RL terminal function selection
0 to 5, 7, 8, 10, 12, 14 to 16,
18, 24, 25, 62, 65 to 67,
9999
1
0
180
14
94
2
{
{
{
{
×
{
181
RM terminal function selection
1
1
181
15
95
2
{
{
{
{
×
{
182
RH terminal function selection
1
2
182
16
96
2
{
{
{
{
×
{
183
MRS terminal function selection
1
24
183
17
97
2
{
{
{
{
×
{
184
RES terminal function selection
1
62
184
18
98
2
{
{
{
{
×
{
F
unc
ti
on
[Pr.]
Name
Setting Range
Minimum Setting
Increments
Initial Value
Refer to
Page
[Pr.]
Option
Instruction Code
Control Mode-based Correspondence
Table
P
ara
met
er
Co
py
P
ara
met
er
Cle
a
r
Al
l P
ara
met
e
r
Cle
a
r
Re
ad
Wr
it
e
E
xt
e
nde
d
V/F control
Advanced
magnetic
flux vector
control
General-
purpose
magnetic-
flux vector
control
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...