46
SPECIFICATIONS
(5) Function assignment to analog input terminal 1, terminal 4, and terminal 6 (FR-A7AZ)
Functions of terminal 1, terminal 4, and terminal 6
(FR-A7AZ) of analog input can be selected and
changed by parameter.
For the terminal 1, terminal 4, and terminal 6 (FR-
A7AZ) used for analog input, frequency (speed)
command, torque command, etc. can be selected. In
addition, functions change according to the control
mode.
z
Terminal 1 function according to control
z
Terminal 4 function according to control
—
: No function
*1
When the same value (1 or 4) is set in [
Pr. 868, 858
], terminal 1 is made valid and terminal 4 has no function.
*2
When [
Pr. 858 = 1, 4
], functions of terminal 4 become valid independently of whether the terminal AU is ON or OFF.
A700
[
Pr.
]
Name
Initial Value
Setting Range
Description
406
High resolution analog input
selection
9999
0, 2 to 6, 9999
Selection of terminal 6 function
(refer to the table below)
858
Terminal 4 function assignment
0
0, 1, 4, 9999
Selection of terminal 4 function
(refer to the table below)
868
Terminal 1 function assignment
0
0 to 6, 9999
Selection of terminal 1 function
(refer to the table below)
[
Pr. 868
]
setting
V/F Control,
Advanced Magnetic Flux
Vector Control
Real Sensorless Vector Control,
Vector Control
Vector Control
Speed control
Torque control
Position control
0
(initial
value)
Frequency setting auxiliary
Speed setting auxiliary
Speed limit auxiliary
—
1
*1
—
Magnetic flux command
Magnetic flux command
Magnetic flux command
2
—
Regenerative torque
limit ([
Pr. 810 = 1
])
—
Regenerative torque limit
[
Pr. 810 = 1
]
3
—
—
Torque command
([
Pr. 804 = 0
]
—
4
*1
Stall prevention operation level
input
Torque limit
[
Pr. 810 = 1
]
Torque command
([
Pr. 804 = 0
]
Torque limit
[
Pr. 810 = 1
]
5
—
—
Forward/reverse rotation
speed limit
([
Pr. 807 = 2
]
—
6
—
Torque bias input
[
Pr. 840 = 1, 2, 3
]
—
—
9999
—
—
—
—
[
Pr. 858
]
Setting
V/F Control, Advanced
Magnetic Flux Vector Control
Real Sensorless Vector Control,
Vector Control
Vector Control
Speed control
Torque control
Position Control
0
(initial
value)
Frequency command
(AU signal-ON)
Speed command
(AU signal-ON)
Speed limit
(AU signal-ON)
—
1
*1 *2
—
Magnetic flux command
Magnetic flux command
Magnetic flux command
4
*1 *2
Stall prevention operation level input
Torque limit
[
Pr. 810 = 1
]
—
Torque limit
[
Pr. 810 = 1
]
9999
—
—
—
—
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...