383
PARAMETER
2
P
ARAM
ETE
R
(3) PU Stop Selection
When [
Pr. 75
= 14 to 17], the motor can be stopped by
pressing
of the PU in any of the PU operation,
External operation and Network operation modes.
Even if [
Pr. 250 Stop selection
≠
9999] is set to select
coasting to a stop, the motor will not coast to stop but
decelerate to stop by the PU stop function during
external operation.
When the inverter is stopped by the PU stop function
in other than PU operation mode,
is displayed
on the PU. A fault signal is not provided.
When [
Pr. 75
= 0 to 3], deceleration to stop by
is
valid only in the PU operation mode.
How to restart the motor (cancel PU stop (PS)) by
input from the PU in the External operation
mode is shown below.
(a) Operation panel (FR-DU07)
(b) Parameter unit (FR-PU04/FR-PU07)
The motor can be restarted by making a reset using a
power supply reset or RES signal.
1) After completion of deceleration to a stop,
switch OFF the STF or STR signal.
2) Press to
display .
.............(
reset)
3) Press
to return to
.
4) Turn ON the STF or STR signal.
1) After completion of deceleration to a stop,
switch OFF the STF or STR signal.
2) Press .
.............(
reset)
3) Turn ON the STF or STR signal.
Speed
Time
Key
Key
Stop/restart example for external operation
Operation
panel
STF ON
(STR) OFF
twice
EXT