5
1
S
PECIFI
C
A
T
IONS
SPECIFICATIONS
Type FR-F740-
K
75
90
110
132
160
185
220
250
280
315
355
400
450
500
560
Applicable motor capacity
(kW)
*1
75
90
110
132
160
185
220
250
280
315
355
400
450
500
560
Ou
tp
u
t
Rated capacity (kVA)
*2
110
137
165
198
247
275
329
366
416
464
520
586
659
733
833
Rated current (A)
*3
144
(122)
180
(153)
216
(183)
260
(221)
325
(276)
361
(306)
432
(367)
481
(408)
547
(464)
610
(518)
683
(580)
770
(654)
866
(736)
962
(817)
1094
(929)
Overload current rating
*4
120% 60s, 150% 3s (inverse-time characteristics)
Voltage
*5
Three-phase 380 to 480V
Regenerative
braking torque
Maximum value/
permissible duty
10% torque/continuous
P
o
wer supply
Rated input AC voltage/
frequency
Three-phase 380 to 480V 50Hz/60Hz
Permissible AC voltage
fluctuation
323 to 528V 50Hz/60Hz
Permissible frequency
fluctuation
±5%
Power supply
system
capacity
(kVA)
*6
Without DC
reactor
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
With DC
reactor
110
137
165
198
247
275
329
366
416
464
520
586
659
733
833
Protective structure (JEM
1030)
*8
Open type (IP00)
Cooling system
Forced air cooling
Approximate mass (kg)
37
50
57
72
72
110
110
175
175
175
260
260
370
370
370
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 220V for 200V class and 440V for 400V class.
*3
When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency will automatically decrease
if the output current of the inverter exceeds the value in parenthesis of the rated current. This may cause the motor noise to
increase.
*4
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current.
For repeated duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed
within the setting range. However, the pulse voltage value of the inverter output side voltage remains unchanged at about
that of the power supply.
*6
The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input
reactor and cables).
*7
When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type
(IP00).
*8
FR-DU07 : IP40 (except for the PU connector)