305
2
P
ARAM
ETE
R
PARAMETER
(2) Set the forward rotation and reverse
rotation individually.
[
Pr. 807
= 1,
Pr. 808, 809
]
Set the speed limit during forward rotation using [
Pr.
808 Forward rotation speed limit
] and the speed limit
during reverse rotation using [
Pr. 809 Reverse rotation
speed limit
].
The speed during forward and reverse rotation is
limited at the setting value of [
Pr. 808
] when [
Pr. 809
=
9999] (initial value).
The speed limit value changes according to
acceleration/deceleration time of [
Pr. 7, Pr. 8
].
(3) Forward rotation/reverse rotation speed
limit [
Pr. 807 = 2, C12 to C15(Pr. 917, 918), C30
to C33(Pr. 926, 927)
]
When making a speed limit using analog input to
terminal 1 or terminal 6 (FR-A7AZ), the speed limit of
the forward and reverse rotation can be switched
according to the polarity of voltage.
Forward/reverse rotation speed limit is valid when [
Pr.
868 Terminal 1 function assignment
= 5]. (Refer to page
for details of terminal1 function assignment)
Set [
Pr. 406 High resolution analog input selection
= 5] to
limit forward/reverse rotation speed using terminal 6
(FR-A7AZ). When [
Pr. 406
= 5] and [
Pr. 868
= 5],
terminal 6 is the forward/reverse speed limit, and
terminal 1 does not have a function.
Speed limit by analog terminal input can be calibrated
using calibration parameter [
C12
to
15
(
Pr. 917, Pr.
918
)], [
C34
to
37
(
Pr. 928, Pr. 929
)].
For 0 to 10V input, set the forward rotation speed
limit. The reverse rotation speed limit at this time is
the value of [
Pr. 1 Maximum frequency
]. The speed limit
value does not follow acceleration/deceleration time
of [
Pr. 7 and Pr. 8
].
For -10 to 0V input, set the reverse rotation speed
limit. The forward rotation speed limit at this time is
the value of [
Pr. 1 Maximum frequency
] .The forward
rotation speed limit does not follow acceleration/
deceleration time of [
Pr. 7, Pr. 8
].
The maximum speed of both the forward and reverse
rotations is [
Pr. 1Maximum frequency
].
[
Pr. 7
]
[
Pr. 8
]
STF (STR)
ON
OFF
Speed limit
Speed limit
Forward rotation
[
Pr. 808
]
[
Pr. 809
]
[
Pr. 809
]
[
Pr. 809
]
Torque controllable range
Torque controllable range
Torque controllable range
Time
Time
Time
Reverse rotation
60Hz
0
Frequency setting signal
10V
Initial value
Bias
[
C14 (Pr.918)
]
Gain
[
C12 (Pr.917)
]
[
C13 (Pr.917)
]
[
C15 (Pr.918)
]
Output
frequency
(Hz)
Example of terminal 1 calibration
60Hz
0
Frequency setting signal
10V
Initial value
Bias
[
C32 (Pr.927)
]
Gain
[
C30 (Pr.926)
]
[
C31 (Pr.926)
]
[
C33 (Pr.927)
]
Output
frequency
(Hz)
Example of terminal 6 (FR-A7AZ) calibration
[
Pr. 7
]
ON
OFF
Start signal
Speed
Time
Torque controllable range
Terminal 1 (6)
input (-10 to 0V)
The reverse
rotation speed
limit
[
Pr. 8
]
[
Pr. 1
]
[
Pr. 7
]
ON
OFF
Start signal
Speed
Time
Terminal 1 (6) input (0 to 10V)
The forward rotation speed
limit
[
Pr. 8
]
[
Pr. 1
]
Torque controllable range
The reverse rotation
speed limit
The forward rotation
speed limit
When terminal 1 or terminal 6 (FR-A7AZ) input is "0 to 10V"
When terminal 1 or terminal 6 (FR-A7AZ) input is "-10 to 0V"