2.15.2 Monitor display selection of the DU/PU, terminal FM/AM, terminal AM0/AM1
(FR-A7AY), terminal DA1 (FR-A7AZ) [Pr. 52, 54, 158*, 170, 171, 268, 306*, 310*,
563, 564, 838*, 891*]
(common)
The monitor to be displayed on the main screen of the
operation panel (FR-DU07)/parameter unit (FR-PU04/FR-
PU07) can be selected.
In addition, signal to be output to terminal FM (pulse train
output), AM (analog voltage output), AM0 (FR-A7AY
analog voltage output), AM1 (FR-A7AY analog current
output), and DA1 (FR-A7AZ bipolar analog voltage output)
can be selected.
(*[
Pr. 838
] is not available for
.)
(*[
Pr. 158, 838, 891
] are not available for
.)
(*[
Pr. 158, 306, 310, 838
] are not available for
.)
common
F700
E700
D700
[Pr. ]
Name
Initial
Value
Setting Range
Description
Available Inverters
52
*
DU/PU main display
data selection
0
(output
frequency)
0, 5 to 14, 17 to 20, 22 to 25,
32 to 35, 50 to 57, 100
Selects the monitor to be
displayed on the operation
panel and parameter unit.
Refer to the table on the next
page for monitor description
{
{
{
{
0, 5, 6, 8 to 14, 17, 20, 23 to
25, 50 to 57, 100
0, 5, 7 to 12, 14, 20, 23 to
25, 52 to 57, 61, 62, 100
0, 5, 8 to 12, 14, 20, 23 to
25, 52 to 55, 61, 62, 64, 100
54
*
FM terminal function
selection
1
(output
frequency)
1 to 3, 5 to 14, 17, 18, 21,
24, 32 to 34, 50, 52, 53
Select the monitor output to
terminal FM.
{
{
{
{
158
*
AM terminal function
selection
1 to 3, 5, 6, 8 to 14, 17, 21,
24, 50, 52, 53
Select the monitor output to
terminal AM.
{
{
—
—
306
*
Analog output signal
selection
2
(output
current)
1 to 3, 5, 7 to 12, 14, 21, 24,
52, 53, 61, 62
Select monitor to be output to
terminal AM0 and AM1 of the
plug-in option FR-A7AY.
{
{
{
—
310
*
Analog meter voltage
output selection
1 to 3, 5, 8 to 12, 14, 21, 24,
52, 53, 61, 62
838
*
DA1 terminal function
selection
2
(output
current)
1 to 3, 5 to 14, 17, 18, 21, 24, 32 to
34, 36, 50, 52, 53
Select the monitor to be output
from terminal DA1 of the plug-
in option FR-A7AZ.
{
—
—
—
170
Watt-hour meter
clear
9999
0
Set 0 to clear the watt-hour
meter monitor.
{
{
{
{
10
Set the maximum value when
monitoring from
communication to 0 to
9999kWh.
9999
Set the maximum value when
monitoring from
communication to 0 to
65535kWh.
171
Operation hour meter
clear
9999
0
,
9999
Set "0" to clear the operation
time monitor.
Setting 9999 has no effect.
{
{
{
{
268
*
Monitor decimal
digits selection
9999
0
Displayed as integral value
{
{
{
{
1
Displayed in 0.1 increments.
9999
No function
563
Energization time
carrying-over times
0
0 to 65535
(reading only)
The numbers of cumulative
energization time monitor
exceeded 65535h is displayed.
Reading only
{
{
{
{
A700
F700
E700
D700
A700
F700
E700
D700
A700
F700
E700
D700