![Mitsubishi Electric FR-A700 Series Technical Manual Download Page 405](http://html.mh-extra.com/html/mitsubishi-electric/fr-a700-series/fr-a700-series_technical-manual_239199405.webp)
439
PARAMETER
2
P
ARAM
ETE
R
*1
As set in [
Pr. 338 Communication operation command source
], [
Pr. 339 communication speed command source
]. (Refer to page 440)
*2
At occurrence of RS-485 communication error, the inverter cannot be reset from the computer.
*3
Enabled only when stopped by the PU. At a PU stop, PS is displayed on the operation panel. As set in [
Pr. 75 PU stop selection
]. (Refer to
*4
Some parameters may be write-disabled according to the [
Pr. 77 Parameter write selection
] setting and operating status. Refer to page
*5
Some parameters are write-enabled independently of the operation mode and command source presence/absence. When [
Pr. 77 = 2
] ,
write is enabled. (Refer to the parameter list on page 120) Parameter clear is disabled.
*6
When [
Pr. 550 NET mode operation command source selection = 1
] (RS-485 terminals valid) or [
Pr. 550 NET mode operation command source
selection = 9999
] and the communication option is not fitted.
*7
When [
Pr. 550 NET mode operation command source selection = 0
] (communication option is valid) or [
Pr. 550 NET mode operation command
source selection = 9999
] and the communication option is fitted.
*8
No communication option is installed when [
Pr.550 NET mode operation command source selection =2
] (PU connector valid) or [
Pr.550 NET
mode operation command source selection = 9999
]
*9
Not available for
.
*10 Not available for
.
*11 Not available for
.
(4) Operation at error occurrence
F700
E700
D700
Alarm
Description
[Pr. 551]
Setting
Operation Mode
PU
Operation
External
Operation
External/PU
Combined
Operation
Mode 1
([Pr. 79 = 3])
External/PU
Combined
Operation
Mode 2
([Pr. 79 = 4])
NET Operation
RS-485
terminals
*5
PU
connector
*7
Communication
option
*6*10
Inverter fault
—
Stop
PU
disconnection of
the PU
connector
2 (PU connector)
9999 (automatic
recognition)
Stop/continued
*1, 4
Other than 2
Stop/continued
*1
Communication
error of PU
connector
2 (PU connector)
Stop/
continued
*2
Continued
Stop/continued
*2
Continued
—
Continued
Other than 2
Continued
Stop/
continued
*2
Continued
Communication
error of RS-485
terminals
*9*10
1 (RS-485
terminals)
Stop/
continued
*2
Continued
Stop/continued
*2
Continued
—
Continued
Other than 1
Continued
Stop/
continued
*2
—
Continued
Communication
error of USB
connector
*8*10
3 (USB connector)
9999 (automatic
recognition)
Stop/
continued
*2
Continued
Stop/continued
*2
Continued
Other than 3
Continued
Communication
error of
communication
option
*10
—
Continued
Stop/continued
*3
*1
Can be selected using [
Pr. 75 Reset selection/disconnected PU detection/PU stop selection
].
*2
Can be selected using [
Pr. 122 PU communication check time interval
], [
Pr. 336 RS-485 communication check time interval
], and [
Pr. 548
USB communication check time interval
].
*3
As controlled by the communication option.
*4
In the PU Jog operation mode, operation is always stopped when the PU is disconnected. Whether error (E.PUE) occurrence is
allowed or not is as set in [
Pr. 75 Reset selection/disconnected PU detection/PU stop selection
].
*5
When [
Pr. 550 NET mode operation command source selection = 1
] (RS-485 terminals valid) or [
Pr. 550 NET mode operation command
source selection = 9999
] and the communication option is not fitted.
*6
When [
Pr. 550 NET mode operation command source selection = 0
] (communication option is valid) or [
Pr. 550 NET mode operation
command source selection = 9999
] and the communication option is fitted.
*7
No communication option is installed when [
Pr.550 NET mode operation command source selection =2
] (PU connector valid) or [
Pr.550 NET
mode operation command source selection = 9999
]
*8
Not available for
.
*9
Not available for
.
*10 Not available for
.
A700
F700
E700
D700
F700
E700
D700
Summary of Contents for FR-A700 Series
Page 245: ...279 2 PARAMETER PARAMETER MEMO ...
Page 440: ...474 PARAMETER MEMO ...
Page 522: ...556 SELECTION MEMO ...