Safety Precautions
1-3
5.
This system is not water-proof designed. DO NOT use
this system in any place where water or any liquid
leakage may occur. If any water is sprayed on or into
the system, electric shock or device malfunction may
result. If water is accidentally sprayed on or into the
system, power off the system immediately and contact
Mindray Customer Service Department or sales
representative.
6.
DO NOT use a probe that has a damaged, scratched
surface, or exposed wiring of any kind. Immediately
stop using the probe and contact Mindray Customer
Service Department or sales representative. There is
risk of electric shock if a damaged or scratched probe
is used.
7.
DO NOT allow the patient to contact the live parts of the
ultrasound system or other devices, e.g. signal I/O
ports. Electric shock may occur.
8.
Do not use an aftermarket probe other than those
specified by Mindray. The probes may damage the
system, causing a profound failure, e.g. a fire in the
worst case.
9.
Do not subject the probes to knocks or drops. Use of a
defective probe may cause an electric shock.
10. Do not open the covers and front panel of the system.
Short circuit or electric shock may result when the
system hardware is exposed and powered on.
11. DO NOT use this system simultaneously with
equipment such as an electrosurgical unit,
high-frequency therapy equipment, or a defibrillator,
etc. Otherwise, there is a risk of electric shock to the
patient.
12. Only use the ECG leads provided with the ECG module;
otherwise electric shock may result.
13. When moving the system, you should hold the handle;
otherwise, damage may be resulted by abnormal force.
DO NOT push the system from the left/right side,
otherwise, it may be toppled over.
14. The auxiliary power output outlet in the system is used
to supply power for the recommended peripheral
devices. DO NOT connect other devices to the outlet,
otherwise, the rated output power may be exceeded
and failure may be resulted. Maximum output power of
the outlet is 240VA.
Summary of Contents for DC-T6
Page 1: ...DC T6 Diagnostic Ultrasound System Operator s Manual Basic Volume...
Page 2: ......
Page 10: ......
Page 16: ......
Page 28: ......
Page 37: ...System Overview 2 9 2 6 Introduction of Each Unit...
Page 178: ......
Page 182: ......
Page 236: ......
Page 240: ...13 4 Probes and Biopsy No Probe Model Type Illustration 19 CW2s Pencil probe...
Page 300: ......
Page 314: ......
Page 320: ......
Page 326: ......
Page 330: ...C 4 Barcode Reader...
Page 337: ...Barcode Reader C 11...
Page 342: ......
Page 347: ...P N 046 001523 01 V1 0...