5-34 Image Optimization
Delete the Sample Line
Click the sample line to select it, and click [Delete] to delete the selected line and you can
re-depict a new sample line.
Tips:
Parameters of Free Xros M mode and Free Xros CM mode are dependent from each
other, but their functions are the same, parameters of Free Xros CM are not to be
introduced, please refer to relevant sections of the M mode and Free Xros M mode.
5.9 TDI
TDI mode is intended to provide information of low-velocity tissue motion, specifically for
cardiac movement.
There are 4 types of TDI mode:
z
Tissue Velocity Imaging (TVI): This imaging mode is used to detect tissue
movement with direction and speed information.
z
Tissue Energy Imaging (TEI): This imaging mode reflects the status of cardiac
movement by displaying the intensity of tissue, the brighter the color the less the
intensity.
z
Tissue Velocity Doppler Imaging (TVD): This imaging mode provides direction
and speed information of the tissue quantificationally with doppler spectrum.
z
Tissue Velocity M Imaging (TVM): This function assists to observe the cardiac
motion through a direct angle. TVM mode is also called Color Tissue M mode,
refer to "5.10 Color M Mode" for details.
Only phased probe is valid for TDI function.
5.9.1 TDI Exam Protocol
Enter
TDI
z
User-defined shortcut key
a) Assign a user-defined shortcut key for TDI: the setting path is "[Setup]
→
[System Preset]
→
[Key Config]". Please refer to "15.1.7 Key Config” for
details.
b) Press the user-defined key in B mode to enter TVI mode.
z
In real-time mode, click [TDI] in the soft menu or menu to enter the corresponding
TDI mode as follows:
h
In Color mode, click [TDI] to enter TVI mode, parameters of TVI mode will be
displayed in the soft menu.
h
In Power mode, click [TDI] to enter TEI mode, parameters of TEI mode will
be displayed in the soft menu.
h
In PW mode, click [TDI] to enter TVD mode, parameters of TVD mode will be
displayed in the soft menu.
h
In M mode, click [TDI] to enter TVM mode, parameters of TVM mode will be
displayed in the soft menu.
Switching between the TDI modes
In TDI mode, press <Color>, <Power>, <M> or <PW> to switch between the modes.
Exit
TDI
z
Click [TDI] or press the user-defined key to exit TDI mode and enter general
imaging modes.
z
Or, press <B> on the control panel to return to B mode.
Summary of Contents for DC-T6
Page 1: ...DC T6 Diagnostic Ultrasound System Operator s Manual Basic Volume...
Page 2: ......
Page 10: ......
Page 16: ......
Page 28: ......
Page 37: ...System Overview 2 9 2 6 Introduction of Each Unit...
Page 178: ......
Page 182: ......
Page 236: ......
Page 240: ...13 4 Probes and Biopsy No Probe Model Type Illustration 19 CW2s Pencil probe...
Page 300: ......
Page 314: ......
Page 320: ......
Page 326: ......
Page 330: ...C 4 Barcode Reader...
Page 337: ...Barcode Reader C 11...
Page 342: ......
Page 347: ...P N 046 001523 01 V1 0...