defect trigger soaking delay: 2500 milliseconds
Operational Status: up
time since last status change: 00:03:30
Loopback State: none
Mode: sonet
Timing source: internal module
Current section alarms: none
Current line alarms : none
Channel configuration:
channel = 1, path = oc1, hierarchy = 1/1/1/1, current path alarms: none
ifAdminStatus: up
snmp trap link-status: disabled
alarms used for operational status calculation: LOP AIS
defect trigger soaking delay: 2500 milliseconds
c2 byte override 20
Operational Status: up
time since last status change: 00:05:37
Ds3 1, unchannelized
ifOperStatus = ifOperUp
snmp trap link-status = disabled
Framing is C-BIT, Line Code is B3ZS, Clock Source is Internal - Module
•
See show controllers sonet.
show controllers sonet ds1|e1
•
Use to display E1 or T1 (DS1) statistics for the different layers in channelized SONET
and SDH interfaces. Figure 8 on page 109 shows the layers in the interface.
•
For definitions of the MIB statistics, see RFC 2495—Definitions of Managed Objects
for the DS1, E1, DS2 and E2 Interface Types (January 1999).
•
Specify an interface in
slot
/
port
format.
•
To view information for a specific controller in a layer, enter the specifier for the
controller and the type for the controller. For example, to view the E1 controller 1/1/1
on path 1 on the interface 4/0, enter
show controllers sonet 4/0:1/1/1/1 e1
.
•
To view information for all controllers above a particular layer, enter the specifier for
the layer and the type for the controller. For example, to view all E1 controllers on the
interface 4/0 path 1, enter
show controllers sonet 4/0:1 e1
.
•
To view E1 or T1 statistics for a layer, specify the controller type, e1 or ds1.
•
To view the configuration for a controller or all controllers in a layer, omit the controller
type.
•
Field descriptions
•
Description—Text description or alias if configured for the interface
•
BERT test—Number of current test and total number of tests
•
Test interval—Length of the BERT test
•
status—Sync (controller is synchronized with remote device) or NoSync (controller
is not synchronized with remote device
153
Copyright © 2010, Juniper Networks, Inc.
Chapter 4: Configuring Channelized OCx/STMx Interfaces
Summary of Contents for JUNOSE 11.2.X MULTICAST ROUTING
Page 6: ...Copyright 2010 Juniper Networks Inc vi...
Page 8: ...Copyright 2010 Juniper Networks Inc viii JunosE 11 2 x Physical Layer Configuration Guide...
Page 16: ...Copyright 2010 Juniper Networks Inc xvi JunosE 11 2 x Physical Layer Configuration Guide...
Page 24: ...Copyright 2010 Juniper Networks Inc 2 JunosE 11 2 x Physical Layer Configuration Guide...
Page 66: ...Copyright 2010 Juniper Networks Inc 44 JunosE 11 2 x Physical Layer Configuration Guide...
Page 228: ...Copyright 2010 Juniper Networks Inc 206 JunosE 11 2 x Physical Layer Configuration Guide...
Page 247: ...PART 2 Index Index on page 227 225 Copyright 2010 Juniper Networks Inc...
Page 248: ...Copyright 2010 Juniper Networks Inc 226 JunosE 11 2 x Physical Layer Configuration Guide...