Far End Unit Identification Code—unit string sent by remote device for MDL
•
Far End Facility Identification Code—pfi string sent by remote device for MDL
•
Far End Generator Number—generator string sent by remote device for MDL
•
Far End Port Number—port string sent by remote device for MDL
•
Number of valid intervals—Number of 15-minute intervals since the line module was
last powered on or reset
•
Time elapse in current interval—Number of seconds that have passed in the 15-minute
(900-second) interval
•
C-bit errored seconds—Number of C-bit errored seconds encountered by a T3 in the
current interval
•
C-bit severely errored seconds—Number of C-bit severely errored seconds
encountered by a T3 in the current interval
•
C-bit coding violations—Number of C-bit coding violations encountered by a T3 in
the current interval
•
Unavailable seconds—Number of unavailable seconds encountered by a T3 in the
current interval
•
Invalid seconds—Number of seconds when statistics were not collected
•
Example—In this example, a T3 interface is specified.
host1#
show controllers t3 5/0 remote
Far End MDL Carrier bit is not set
Far End Equipment Identification Code is the null string
Far End Line Identification Code is the null string
Far End Frame Identification Code is the null string
Far End Unit Identification Code is the null string
Far End Facility Identification Code is the null string
Far End Generator Number is the null string
Far End Port Number is the null string
Number of valid interval - 3
Time elapse in current interval - 756
Ds3 Current Interval Counters
C-bit errored seconds = 0
C-bit severely errored seconds = 0
C-bit coding violations = 0
Unavailable seconds = 0
Invalid seconds = 0
Ds3 Last Interval Counters
C-bit errored seconds = 0
C-bit severely errored seconds = 0
C-bit coding violations = 0
Unavailable seconds = 0
Invalid seconds = 0
Ds3 24 Hour Total Counters
C-bit errored seconds = 1
Copyright © 2010, Juniper Networks, Inc.
38
JunosE 11.2.x Physical Layer Configuration Guide
Summary of Contents for JUNOSE 11.2.X MULTICAST ROUTING
Page 6: ...Copyright 2010 Juniper Networks Inc vi...
Page 8: ...Copyright 2010 Juniper Networks Inc viii JunosE 11 2 x Physical Layer Configuration Guide...
Page 16: ...Copyright 2010 Juniper Networks Inc xvi JunosE 11 2 x Physical Layer Configuration Guide...
Page 24: ...Copyright 2010 Juniper Networks Inc 2 JunosE 11 2 x Physical Layer Configuration Guide...
Page 66: ...Copyright 2010 Juniper Networks Inc 44 JunosE 11 2 x Physical Layer Configuration Guide...
Page 228: ...Copyright 2010 Juniper Networks Inc 206 JunosE 11 2 x Physical Layer Configuration Guide...
Page 247: ...PART 2 Index Index on page 227 225 Copyright 2010 Juniper Networks Inc...
Page 248: ...Copyright 2010 Juniper Networks Inc 226 JunosE 11 2 x Physical Layer Configuration Guide...