Rcv LOF—Loss of one or more frames from the remote end
•
Rcv LOS—Loss of signal at the local end
•
Undefined line status—Indicates that the line is in an undefined state
NOTE:
The alarms detected field does not appear for interfaces that you disabled in
the software.
•
framing—Type of framing format
•
line code—Type of line code format
•
clock source—Type of clock source
•
cable length—Cable length, in feet
•
Loopback—State of loopback for the controller: enabled or disabled. If loopback is
enabled, one of the following states is displayed:
•
Diagnostic—Loops the data back toward the router and sends an AIS toward the
network
•
Payload—Loops the data toward the network after the framer has processed the
data
•
Line—Loops the data toward the network before the data reaches the framer
•
MDL Transmit Path—Status of path transmission: active or not active
•
MDL Transmit Test-Signal—Status of test signal: active or not active
•
MDL Transmit Idle-Signal—Status of idle signal: active or not active
•
Equipment Identification Code—eic string for MDL
•
Line Identification Code—lic string for MDL
•
Frame Identification Code—fic string for MDL
•
Unit Identification Code—unit string for MDL
•
Facility Identification Code—pfi string for MDL
•
Port Code—port string for MDL
•
Generator Number—generator string for MDL
•
BERT test—Number of current test and total number of tests
Copyright © 2010, Juniper Networks, Inc.
30
JunosE 11.2.x Physical Layer Configuration Guide
Summary of Contents for JUNOSE 11.2.X MULTICAST ROUTING
Page 6: ...Copyright 2010 Juniper Networks Inc vi...
Page 8: ...Copyright 2010 Juniper Networks Inc viii JunosE 11 2 x Physical Layer Configuration Guide...
Page 16: ...Copyright 2010 Juniper Networks Inc xvi JunosE 11 2 x Physical Layer Configuration Guide...
Page 24: ...Copyright 2010 Juniper Networks Inc 2 JunosE 11 2 x Physical Layer Configuration Guide...
Page 66: ...Copyright 2010 Juniper Networks Inc 44 JunosE 11 2 x Physical Layer Configuration Guide...
Page 228: ...Copyright 2010 Juniper Networks Inc 206 JunosE 11 2 x Physical Layer Configuration Guide...
Page 247: ...PART 2 Index Index on page 227 225 Copyright 2010 Juniper Networks Inc...
Page 248: ...Copyright 2010 Juniper Networks Inc 226 JunosE 11 2 x Physical Layer Configuration Guide...