— Stratum 3 or better, recovered either from a known good STM port or from one of
the BITS inputs.
•
Although the CLI enables you to specify the keywords
internal module
to use the line
module’s internal clock, in a production network we recommend that you do not do
this. Instead, specify the keywords
internal chassis
to use the router’s internal clock.
•
For production networks, never specify the keyword
line
to use the line’s receive clock
as the transmit clock. Although the CLI enables this configuration, it is not supported
because jitter transfer is not compliant for this timing and because pointer adjustments
takes place on the outgoing link.
•
In a nonproduction network, you can configure some ports with internal clock sources
and others with line clock sources. However, all ports with internal clock sources must
use either the router’s clock or the module’s clock. You cannot configure some ports
on the I/O module to use the router’s clock and others to use the module’s clock.
•
To change the clock source of the ports on a cOC3/STM1 I/O module from the router’s
clock to the module’s clock or vice versa, first change the clock source of all ports to
the line setting, and then to the new internal clock setting.
•
Example
host1(config-controll)#
clock source internal chassis
•
Use the
no
version to revert to the default,
line
.
•
See clock source.
controller sonet
•
Use to select an interface on which you want to configure channelized SONET or SDH.
•
Example
host1(config)#
controller sonet 4/0
•
There is no
no
version.
•
See controller sonet.
description
•
Use to assign a text description or an alias to a channelized SONET interface.
•
You can use this command to help you identify the interface and keep track of interface
connections.
•
The description or alias can be a maximum of 64 characters.
•
Use the
show controllers sonet
command to display the text description.
•
Example
host1(config-controll)#
description boston-sonet-interface
•
Use the
no
version to remove the text description or alias.
•
See description.
path
Copyright © 2010, Juniper Networks, Inc.
116
JunosE 11.2.x Physical Layer Configuration Guide
Summary of Contents for JUNOSE 11.2.X MULTICAST ROUTING
Page 6: ...Copyright 2010 Juniper Networks Inc vi...
Page 8: ...Copyright 2010 Juniper Networks Inc viii JunosE 11 2 x Physical Layer Configuration Guide...
Page 16: ...Copyright 2010 Juniper Networks Inc xvi JunosE 11 2 x Physical Layer Configuration Guide...
Page 24: ...Copyright 2010 Juniper Networks Inc 2 JunosE 11 2 x Physical Layer Configuration Guide...
Page 66: ...Copyright 2010 Juniper Networks Inc 44 JunosE 11 2 x Physical Layer Configuration Guide...
Page 228: ...Copyright 2010 Juniper Networks Inc 206 JunosE 11 2 x Physical Layer Configuration Guide...
Page 247: ...PART 2 Index Index on page 227 225 Copyright 2010 Juniper Networks Inc...
Page 248: ...Copyright 2010 Juniper Networks Inc 226 JunosE 11 2 x Physical Layer Configuration Guide...