<Quidway>
display ntp-service sessions
source reference stra reach poll now offset delay
disper
********************************************************************************
[12345]127.127.1.0 LOCAL(0) 7 1 64 2 - 0.0
15.6
note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured,
6 vpn-instance
Run the
display ntp-service trace
command to view the summary information on each passing
NTP server when tracing from the local device to the reference clock source.
<Quidway>
display ntp-service trace
server 127.0.0.1,stratum 5, offset 0.024099, synch distance 0.06337,
server 171.1.1.2,stratum 4, offset 0.028786, synch distance 0.04575,
server 201.1.1.2,stratum 3, offset 0.035199, synch distance 0.03075,
server 200.1.7.1,stratum 2, offset 0.039855, synch distance 0.01096,
refid 127.127.1.0
3.4 Configuring NTP Security Mechanisms
This section describes how to configure NTP security mechanisms to guarantee reliable clock
synchronization on networks demanding high security.
3.4.1 Establishing the Configuration Task
3.4.2 Setting NTP Access Authorities
3.4.3 Enabling NTP Authentication
3.4.4 Configuring NTP Authentication in Unicast Server/Client Mode
3.4.5 Configuring NTP Authentication in Peer Mode
3.4.6 Configuring NTP Authentication in Broadcast Mode
3.4.7 Configuring NTP Authentication in Multicast Mode
3.4.8 Checking the Configuration
After NTP security mechanisms are configured, you can view the configuration.
3 NTP Configuration
Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management
3-14
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 03 (2010-09-20)