Figure 68 FCIP impact on existing iSCSI configurations — dual fabrics per blade
.
In the dual FC fabric case, the impact is higher because after adding an FCIP Route there is only one
remaining FC port available for iSCSI. Therefore, only the targets from one fabric or the other will be
available to iSCSI initiators connected to that MPX200 blade; access to targets on the other fabric
are through another MPX200 blade.
FCIP and iSCSI performance
In most use cases, mixing iSCSI and FCIP on the same blade will provide adequate performance.
However, high availability/performance goals may dictate a dedicated MPX200 for each function
or protocol. For example, if your performance needs are for more that 8 Gb/s of FC access for iSCSI
alone, configuring FCIP on the same blade would limit FC access to only 8 Gb/s and would not meet
the performance requirements for that situation.
MPX200 iSCSI/FCIP configurations
The MPX200 router supports the following configurations:
• Figure 69
MPX200 basic FCIP configuration with one or two long-distance links
• Figure 70
MPX200 with FCIP and B-series switches with Integrated Routing
• Figure 71
MPX200 high-availability configuration with one or two long-distance links
• Figure 72
MPX200 high-availability with fully-redundant long-distance links
• Figure 73
MPX200 configuration with remote IP distance gateway (mpx110)
• Figure 74
on page 119 MPX200 highly redundant pairs of gateways with one or two long-distance
links
• Figure 75
on page 119 MPX200 highly redundant pairs of gateways with fully-redundant long-
distance links
• Figure 76
on page 120 MPX200 simultaneous iSCSI and FCIP with remote dedicated FCIP blade
• Figure 77
on page 120 MPX200 simultaneous iSCSI and FCIP, both local and remote
MPX200 FCIP
116
Summary of Contents for Storageworks 8100 - enterprise virtual array
Page 20: ...20 ...
Page 30: ...MPX200 Multifunction Router overview 30 ...
Page 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Page 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Page 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Page 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Page 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Page 248: ...Offline Data Migration 248 ...
Page 258: ...Diagnostics and troubleshooting 258 ...
Page 306: ...Command referencecommand reference 306 ...
Page 330: ... Blade number 1 or 2 Simple Network Management Protocol setup 330 ...
Page 368: ...Saving and restoring the MPX200 configuration 368 ...
Page 402: ...Data migration best practices 402 ...
Page 408: ...408 ...