1.
Click
Discovery
. To manually discover iSCSI target portals:
a.
Click
Add
under Target Portals.
b.
Enter the IP address of the iSCSI port of the MPX200.
c.
Click
Advanced
.
d.
Select the CHAP Login Information checkbox.
e.
Enter the CHAP secret for the MPX200-discovered iSCSI initiator in the Target Secret box
(for example,
CHAPsecret01
).
f.
Click
OK
and the initiator completes Target discovery. Using iSNS for target discovery:
• Click
Add
under iSNS Servers.
• Enter the IP address of the iSNS server.
• Click
OK
.
2.
Click
Targets
and select the appropriate target for login.
3.
Click
Log On
and then click
Advanced
.
4.
Select the CHAP Login Information checkbox.
5.
Enter the CHAP secret for the MPX200-discovered iSCSI initiator in the Target Secret box.
6.
Click
OK
.
7.
Click
OK
again.
Enabling CHAP for the open-iscsi iSCSI initiator
To enable CHAP for the open-iscsi iSCSI initiator:
1.
Edit the
/etc/iscsi/iscsid.conf
file:
a.
Enable CHAP for both discovery and normal sessions:
discovery.sendtargets.auth.authmethod=
CHAP
node.session.auth.authmethod=
CHAP
b.
Set up the user name and password for the initiator for a normal session. For example:
# To set a CHAP username and password for initiator
# authentication by the target(s), uncomment the following lines:
#node.session.auth.username =
username
#node.session.auth.password =
password
node.session.auth.username =
iqn.1994-05.com.redhat:fc813cac13.
sanergy33
node.session.auth.password =
CHAPSecret01
c.
Set up the user name and password for the initiator for a discovery session. For example:
# To set a discovery session CHAP username and password for the initiator
# authentication by the target(s), uncomment the following lines:
#discovery.sendtargets.auth.username =
username
#discovery.sendtargets.auth.password =
password
discovery.sendtargets.auth.username =
iqn.1994-05.com.redhat:fc813cac13.
sanergy33
discovery.sendtargets.auth.password =
CHAPSecret01
MPX200 iSCSI configuration rules and guidelines
104
Summary of Contents for Storageworks 8100 - enterprise virtual array
Page 20: ...20 ...
Page 30: ...MPX200 Multifunction Router overview 30 ...
Page 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Page 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Page 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Page 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Page 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Page 248: ...Offline Data Migration 248 ...