LUN mask was removed for LUN
%d
.
Info
User
qapisetlunmask_1_svc:
Lunmask removed for LUN
%d
151895
Management port configuration has changed.
Info
User
qapisetmgmintfc-
params_1_svc:Management
port configuration
changed
151896
Router configuration has changed.
Info
User
qapisetbridgebasi-
cinfo_1_svc:Bridge config-
uration changed
151897
GE port
%d
was enabled user.
Info
User
GE%d: Port status changed
by user to ENABLED.
151908
GE port
%d
was disabled by user.
Info
User
GE%d: Port status changed
by user to DISABLED.
151909
FC port
%d
was enabled by user.
Info
User
FC%d: Port status changed
by user to ENABLED.
151910
FC port
%d
was disabled by user.
Info
User
FC%d: Port status changed
by user to DISABLED.
151911
Target at WWPN:
xx.xx.xx.xx.xx.xx.xx.xx
has
been mapped to iSCSI portal
%d
.
Info
User
qapimaptarget-
device_1_svc: Target
WWPN:
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
mapped to iSCSI portal
%d.
151912
Target at WWPN:
xx.xx.xx.xx.xx.xx.xx.xx
has
been unmapped from iSCSI portal
%d
.
Info
User
qapimaptarget-
device_1_svc: Target
WWPN:
%.2x%.2x%.2x%.2x%.2x%.2x%.2x%.2x
unmapped from iSCSI
portal %d.
151913
Initiators configuration has changed.
Info
User
qapiaddmodifyinitiat-
or_1_svc : Initiator Con-
figuration Changed
152082
Initiator has been removed.
Info
User
qapiremoveinitiator_1_svc
: Initiator Removed
152083
Left power and cooling module (PCM) is or
has been installed.
Info
User
sysTempMon: Left PCM In-
stalled
152129
Left PCM is or has been uninstalled.
Info
User
sysTempMon: Left PCM Un-
installed
152130
Right PCM is or has been installed.
Info
User
sysTempMon: Right PCM In-
stalled
152131
Right PCM is or has been uninstalled.
Info
User
sysTempMon: Right PCM Un-
installed
152132
Log messageslog messages
346
Summary of Contents for Storageworks 8100 - enterprise virtual array
Page 20: ...20 ...
Page 30: ...MPX200 Multifunction Router overview 30 ...
Page 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Page 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Page 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Page 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Page 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Page 248: ...Offline Data Migration 248 ...
Page 258: ...Diagnostics and troubleshooting 258 ...
Page 306: ...Command referencecommand reference 306 ...
Page 330: ... Blade number 1 or 2 Simple Network Management Protocol setup 330 ...
Page 368: ...Saving and restoring the MPX200 configuration 368 ...
Page 402: ...Data migration best practices 402 ...
Page 408: ...408 ...