1.
Update the
sgen
driver:
# update_drv –a –I “scsiclass,0c” sgen
NOTE:
Lowercase
c
is mandatory.
2.
Verify the
sgen
alias setting:
#egrep sgen /etc/driver_aliases
Example:
# rep sgen /etc/driver_aliases
sgen "scsa,08.bfcp"
sgen "scsa,08.bvhci"
sgen "scsiclass,0c"
Enable iSCSI target discovery
Solaris supports three iSCSI target discovery methods:
•
SendTargets
•
Static
•
iSNS
This section describes SendTargets discovery only. For information on static and iSNS discovery, see
http://docs.sun.com/app/docs/doc/817-5093/fqnlk?l=en&=view
.
To enable iSCSI target discovery:
1.
Enter the following command:
# iscsiadm modify discovery –t enable
2.
Verify that SendTargets is enabled:
# iscsiadm list discovery
3.
The MPX200 has multiple iSCSI ports available to the Solaris iSCSI initiator. To discover the
targets available, enter the following command for each iSCSI port IP address that the iSCSI
initiator will access:
#iscsiadm add discovery-address ‘iscsi port IP address’
4.
Verify the discovery address entries:
#iscsiadm list discovery-address
MPX200 Multifunction Router
87
Summary of Contents for Storageworks 8100 - enterprise virtual array
Page 20: ...20 ...
Page 30: ...MPX200 Multifunction Router overview 30 ...
Page 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Page 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Page 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Page 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Page 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Page 248: ...Offline Data Migration 248 ...
Page 258: ...Diagnostics and troubleshooting 258 ...
Page 306: ...Command referencecommand reference 306 ...
Page 330: ... Blade number 1 or 2 Simple Network Management Protocol setup 330 ...
Page 368: ...Saving and restoring the MPX200 configuration 368 ...
Page 402: ...Data migration best practices 402 ...
Page 408: ...408 ...