Requires HP Command View EVA 9.1.1 or later for array-based and server-based management.
•
A maximum of one MPX200 chassis (two blades) can be discovered by an EVA storage system.
•
HP Command View EVA manages the MPX200 out of band (IP) through the MPX200 management
IP port. The HP Command View EVA application server must be on the same IP network as the
MPX200 management IP port.
•
The MPX200 iSCSI initiator and iSCSI LUN masking information resides in the MPX200, not in
the HP Command View EVA database.
•
The default iSCSI initiator EVA host-mode setting is Microsoft Windows. The iSCSI initiator host-
mode setting for Apple Mac OS X, Linux, Sun Solaris, VMware, and Windows 2008 is configured
with HP Command View EVA.
NOTE:
Communication between HP Command View EVA and the MPX200 is not secured by the
communication protocol. If unsecured communication is a concern, HP recommends using a confined
or secured IP network in the data center.
EVA storage system software
EVA storage system software supported for Fibre Channel hosts, such as HP StorageWorks Continuous
Access, Business Copy, Storage System Scripting Utility (SSSU), and Replication Solutions Manager
(RSM), are supported with the MPX200 for EVA LUNs that have been presented to iSCSI initiators.
This section describes restrictions for iSCSI hosts using the MPX200.
Features supported for iSCSI hosts
The following Business Copy features are supported for iSCSI hosts:
•
LUN snapshots presented to iSCSI hosts
•
LUN snapclones (normal or 3-phase) presented to iSCSI hosts
•
Instant restore from a snapclone to the original source
•
Ability of iSCSI hosts to access and write to EVA snapshots and snapclones
•
Use of HP Command View EVA, SSSU, or RSM to create snapshots manually or automatically on
a schedule
•
CLI support to enter replication commands from iSCSI hosts
Features not supported for iSCSI hosts
LUNs that are presented to iSCSI hosts through the MPX200, and that require a host agent on the
iSCSI initiator, do not support advanced replication features because there are no iSCSI replication
host agents available. The following features are not supported for iSCSI hosts:
•
Mounting and unmounting LUNs through a host agent, which must be performed manually
•
Accessing the host's view of storage (for example, viewing an F drive from a host)
•
Deploying host agents to allow users to launch a script on the iSCSI host
Table 5
describes support for EVA storage system software when using the MPX200 for iSCSI.
MPX200 Multifunction Router
51
Summary of Contents for Storageworks 8100 - enterprise virtual array
Page 20: ...20 ...
Page 30: ...MPX200 Multifunction Router overview 30 ...
Page 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Page 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Page 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Page 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Page 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Page 248: ...Offline Data Migration 248 ...
Page 258: ...Diagnostics and troubleshooting 258 ...
Page 306: ...Command referencecommand reference 306 ...
Page 330: ... Blade number 1 or 2 Simple Network Management Protocol setup 330 ...
Page 368: ...Saving and restoring the MPX200 configuration 368 ...
Page 402: ...Data migration best practices 402 ...
Page 408: ...408 ...