Verify that the MPX200 port is registered with the storage
system through the same storage controller port through
which it is trying to access the LUNs. If the MPX200 ports
are registered with SPA-0 port, and SPA-1 port is zoned
with the MPX200 ports on the switch, the MPX200 will
not see any of the assigned LUNs.
On presenting a data LUN for the first time, the router
considers it to be an array reconfiguration scenario,
where the data LUN replaces the controller LUN. To see
the correct LUN details, perform either of these options:
•
In the CLI, issue the
show luninfo
command two
or three times.
•
In the mpx Manager GUI, click
Refresh
two or three
times.
The MPX200 does not show masked LUNs, and
instead shows LUN 0 only with offline status for an
EMC CX array.
Make sure that the LUN state is online for both the source
and destination LUNs. Check whether the zoning config-
uration is valid and that the arrays are shown in an online
state. If the array state is online and the LUN state is off-
line, make sure that the LUN presented to the MPX200
at the time of configuring the job has not been replaced
by another LUN at the time of starting the job. This is a
case of reconfiguration and the associated job will have
to be deleted. For more information, see “
Reconfiguring
LUNs on a storage array
” on page 245.
The MPX200 tries to start a scheduled job and
shows a job in
Pending
state instead of
Running
state.
MPX200 Multifunction Router
247
Summary of Contents for Storageworks 8100 - enterprise virtual array
Page 20: ...20 ...
Page 30: ...MPX200 Multifunction Router overview 30 ...
Page 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Page 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Page 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Page 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Page 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Page 248: ...Offline Data Migration 248 ...
Page 258: ...Diagnostics and troubleshooting 258 ...
Page 306: ...Command referencecommand reference 306 ...
Page 330: ... Blade number 1 or 2 Simple Network Management Protocol setup 330 ...
Page 368: ...Saving and restoring the MPX200 configuration 368 ...
Page 402: ...Data migration best practices 402 ...
Page 408: ...408 ...