If volumes are not managed through a logical volume manager in the system, it is important to follow
the pre-migration checklists to identify the physical device nodes (
/dev/rdsk/c0t1d1
) on which
the volume is mounted. After data migration, the physical device node may change. Change the
volume mount such that it now it points to the new physical device (
dev/rdsk/c0t2d5
).
To discover current active mount points, issue the mount command on the system console.
Some applications, such as the Oracle Cluster File system (OCFS) may directly use the raw devices.
Consult the system administrator. OCFS may discover the migrated devices automatically. Follow the
procedure listed in OCFS manual.
In addition, HP recommends that the destination LUN size is equal to the source LUN size. Expand
the destination LUN after the migration is complete and the migrated volume is remounted.
If you are running Veritas Volume Manager on any of the UNIX operating systems, the destination
LUN size must be greater than the source LUN size.
Checklist examples
This section provides examples of completed data migration checklists. These examples depict a
scenario where a customer is upgrading from an old EMC CX3-20 storage array to a new HP EVA
4400 storage array. Three applications and servers are using the CX3-20 array. Each of these three
servers has a different operating system. The information shown with
bold
text in these tables represents
changes from the existing configuration.
Step 1. List the source and destination storage array
Table 43 Example: Storage array information
WWPN
2
(Fibre Channel)
Number
of con-
trollers
Array man-
agement soft-
ware
1
Firmware
version
Source/des-
tination
Storage array
50-06-01-60-41-e0-18-94
nl
50-06-01-61-41-e0-18-94
nl
50-06-01-62-41-e0-18-94
nl
50-06-01-63-41-e0-18-94
2
Navisphere
03.24.040.5.0
06
Source
EMC CX3-20
50-00-1F-E1-50-06-22-A1
nl
50-00-1F-E1-50-06-22-A2
nl
50-00-1F-E1-50-06-22-A2
nl
50-00-1F-E1-50-06-22-A3
nl
50-00-1F-E1-50-06-22-A4
2
Command
View
CR0D63xc3 p-
6000
Destination
HP EVA 4400
1
The storage array-specific software that is used in data migration to present the source LUNs to the MPX200, and to create
destination LUNs to be presented to the MPX200 and to the server. The array management software also provides the controller
and WWPN information for the storage array ports.
2
World wide port name of the Fibre Channel array; used in performing zoning in Fibre Channel switch firmware.
Data migration best practices
376
Summary of Contents for Storageworks 8100 - enterprise virtual array
Page 20: ...20 ...
Page 30: ...MPX200 Multifunction Router overview 30 ...
Page 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Page 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Page 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Page 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Page 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Page 248: ...Offline Data Migration 248 ...
Page 258: ...Diagnostics and troubleshooting 258 ...
Page 306: ...Command referencecommand reference 306 ...
Page 330: ... Blade number 1 or 2 Simple Network Management Protocol setup 330 ...
Page 368: ...Saving and restoring the MPX200 configuration 368 ...
Page 402: ...Data migration best practices 402 ...
Page 408: ...408 ...