Redundant FCIP network structure example
In a high-availability FCIP configuration, pairs of MPX200 routers and two independent IP networks
provide full redundancy. Loss of connectivity through one of the IP networks will not result in a loss of
connectivity between the fabrics.
The redundant configuration can be either a single HP StorageWorks MPX200 Multifunction Router
1–GbE Base Chassis with a HP StorageWorks MPX200 Router 1–GbE Upgrade Blade, or an HP
StorageWorks MPX200 Multifunction Router 10–1 GbE Base Chassis with a HP StorageWorks
MPX200 Router 10–1 GbE Upgrade Blade. Note that FCIP is currently supported only on MPX200
1 GbE ports. See
Figure 66
.
Figure 66 MPX200 high-availability configuration with fully-redundant long-distance links
.
Using FCIP to encapsulate FC packets
With FCIP, gateways transport FC frames over an IP network. From the perspective of the local and
remote fabrics, the FC devices accessed through the gateways appear to be part of one unified fabric.
This is possible because FC traffic is carried over the IP network in such a way that the FC fabric and
all FC devices on the fabric are unaware of the presence of the IP network. Once configured, FCIP
instances on each gateway become active and establish their connectivity through the IP network.
The FC devices in the local fabric access the FC devices in the remote fabric using FC frames. The
FC frames are encapsulated in IP packets by the local gateway and then transmitted to the remote
gateway. The remote gateway strips the IP packet data and passes only the FC frames to the remote
FC devices. The gateways deployed for FCIP are configured to use TCP, which uses standard TCP
flow control and error recovery algorithms.
FCIP Impact on existing iSCSI configurations
This guide includes samples of FCIP and iSCSI configurations to illustrate some of the many possible
configurations available. Despite the number of permutations, there are really only two basic FCIP
configurations: a
dedicated FCIP blade
and a
shared iSCSI/FCIP blade
.
A dedicated MPX200 blade running only FCIP will not have any impact on a dedicated MPX200
blade running iSCSI. There is, however, an impact and possibly changes required for existing MPX200
iSCSI configurations when FCIP is added to the same blade. This must also be considered when
planning a new iSCSI/FCIP mixed blade configuration.
MPX200 FCIP
114
Summary of Contents for Storageworks 8100 - enterprise virtual array
Page 20: ...20 ...
Page 30: ...MPX200 Multifunction Router overview 30 ...
Page 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Page 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Page 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Page 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Page 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Page 248: ...Offline Data Migration 248 ...
Page 258: ...Diagnostics and troubleshooting 258 ...
Page 306: ...Command referencecommand reference 306 ...
Page 330: ... Blade number 1 or 2 Simple Network Management Protocol setup 330 ...
Page 368: ...Saving and restoring the MPX200 configuration 368 ...
Page 402: ...Data migration best practices 402 ...
Page 408: ...408 ...