Driver’s initiator database is full. The driver is
capable of storing 1024 iSCSI initiators in its
database. Use the CLI or GUI to remove un-
wanted/unused iSCSI initiators.
Error
iSCSI
#%d: QLUpdateInitiat-
orData: No more room in
Initiator Database.
74784
Driver’s target database is full. Use the CLI or
GUI to remove unwanted/unused iSCSI tar-
gets.
Error
iSCSI
#%d: QLSetTargetData: No
more room in Target Data-
base.
74800
TCP retry for a frame failed on the connection
ddbIndex. Tpb
contains the frame memory
address.
Error
iSCSI
#%d: ql_process_error:
OB_TCP_IOCB_RSP_W re-
turned DdbInx 0x%x pTpb
%p
75008
Restart iSCSI processor (RISC).
Info
iSCSI
#%d: QLDisable: Restart
RISC
86347
EEPROM updated, restart iSCSI processor
(RISC).
Info
iSCSI
#%d: QLEnable: Restart
RISC to update EEPROM
86349
Link up reported by iSCSI processor for GE1
or GE 2.
Info
iSCSI
#%d: QLIsrDecodeMailbox:
Link up
86874
iSCSI controller reported a link speed/config-
uration of 100 Mb full-duplex (FDX).
Info
iSCSI
#%d: QLGetFwStateCall-
back: link 100Mb FDX
87346
iSCSI controller reported a link speed/config-
uration of 1000 Mb FDX.
Info
iSCSI
#%d: QLGetFwStateCall-
back: link 1000Mb FDX
87348
iSCSI controller reported an invalid link speed.
Info
iSCSI
#%d: QLGetFwStateCall-
back: Invalid link speed
0x%x
87350
FC1 processor SRAM test failed.
Fatal
FC
#%d: qlutm_init: Diagnost-
ic failed, port 1 invalid
SRAM
102419
FC1 processor power-on self-test (POST) failed.
Fatal
FC
#%d: qlutm_init: Diagnost-
ic failed, port 1 POST
failed
102420
FC2 processor SRAM test failed.
Fatal
FC
#%d: qlutm_init: Diagnost-
ic failed, port 2 invalid
SRAM
102421
FC2 processor POST failed.
Fatal
FC
#%d: qlutm_init: Diagnost-
ic failed, port 2 POST
failed
102422
FC processor failed to return diagnostic results.
Fatal
FC
#%d: qlutm_init: Failed
to return diagnostic res-
ult to Bridge
102423
FC processor failed reset.
Fatal
FC
#%d: QLInitializeAdapter:
Reset ISP failed
102656
FC processor firmware load failed.
Fatal
FC
#%d: QLInitializeAdapter:
Load RISC code failed
102657
Log messageslog messages
340
Summary of Contents for Storageworks 8100 - enterprise virtual array
Page 20: ...20 ...
Page 30: ...MPX200 Multifunction Router overview 30 ...
Page 47: ...Figure 27 iSCSI controller options Remove controller MPX200 Multifunction Router 47 ...
Page 48: ...Managing the MPX200 using HP Command View EVA 48 ...
Page 59: ...Figure 32 Virtual disk properties Figure 33 Host details MPX200 Multifunction Router 59 ...
Page 112: ...MPX200 iSCSI configuration rules and guidelines 112 ...
Page 219: ...Load Balancing Enabled Array License Not Applied MPX200 Multifunction Router 219 ...
Page 248: ...Offline Data Migration 248 ...
Page 258: ...Diagnostics and troubleshooting 258 ...
Page 306: ...Command referencecommand reference 306 ...
Page 330: ... Blade number 1 or 2 Simple Network Management Protocol setup 330 ...
Page 368: ...Saving and restoring the MPX200 configuration 368 ...
Page 402: ...Data migration best practices 402 ...
Page 408: ...408 ...