b031
≠
10 b031=10
In
tel
lig
en
t o
u
tp
u
t
ter
m
in
al
s
C021
Terminal [11] function
00 (RUN: running), 01 (FA1: constant-speed reached),
02 (FA2: set frequency overreached),
03 (OL: overload notice advance signal (1)),
04 (OD: output deviation for PID control),
05 (AL: alarm signal),
06 (FA3: set frequency reached), 07 (OTQ: over-torque),
08 (IP: instantaneous power failure),
09 (UV: under voltage), 10 (TRQ: torque limited),
11 (RNT: operation time over), 12 (ONT: plug-in time over),
13 (THM: thermal alarm signal), 19(BRK:brakge release), 20(BER:braking
error)21 (ZS: 0 Hz detection signal), 22(DSE:speed deviation maximum),
23(POK:positioning completed),
24 (FA4: set frequency overreached 2),
25 (FA5: set frequency reached 2),
26 (OL2: overload notice advance signal (2)),
27 (Odc: Analog O disconnection detection),
28 (OIDc: Analog OI disconnection detection),
29 (O2Dc: Analog O2 disconnection detection),
31 (FBV: PID feedback comparison),
32 (NDc: communication line disconnection),
33 (LOG1: logical operation result 1),
34 (LOG2: logical operation result 2),
35 (LOG3: logical operation result 3),
36 (LOG4: logical operation result 4),
37 (LOG5: logical operation result 5),
38 (LOG6: logical operation result 6),
39 (WAC: capacitor life warning),
40 (WAF: cooling-fan speed drop),
41 (FR: starting contact signal),
42 (OHF: heat sink overheat warning),
43 (LOC: low-current indication signal),
44 (M01: general-purpose output 1),
45 (M02: general-purpose output 2),
46 (M03: general-purpose output 3),
47 (M04: general-purpose output 4),
48 (M05: general-purpose output 5),
49 (M06: general-purpose output 6),
50 (IRDY: inverter ready), 51 (FWR: forward rotation),
52 (RVR: reverse rotation), 53 (MJA: major failure),
54(WCO: window comparator O),
55(WCOI: window comparator OI),
56 (WCO2: window comparator O2)
(When alarm code output is selected for "C062", functions "AC0" to "AC2"
or "AC0" to "AC3" [ACn: alarm code output] are forcibly assigned to
intelligent output terminals 11 to 13 or 11 to 14, respectively.)
01
Not
Allowed
4-60
C022
Terminal [12] function
00
Not
Allowed
C023
Terminal [13] function
03
Not
Allowed
C024
Terminal [14] function
07
Not
Allowed
C025
Terminal [15] function
40
Not
Allowed
C026
Alarm relay terminal function
05
Not
Allowed
A
n
al
o
g m
o
n
it
o
ri
n
g
C027
[FM] siginal selection
00 (output frequency), 01 (output current),
02 (output torque), 03 (digital output frequency),
04 (output voltage), 05 (input power),
06 (electronic thermal overload), 07 (LAD frequency),
08 (digital current monitoring), 09 (motor temperature),
10 (heat sink temperature), 12 (general-purpose output YA0)
00
Not
Allowed 4-73
C028
[AM] siginal selection
00 (output frequency), 01 (output current),
02 (output torque), 04 (output voltage), 05 (input power), 06 (electronic
thermal overload), 07 (LAD frequency),
09 (motor temperature), 10 (heat sink temperature),
11 (output torque [signed value]), 13 (general-purpose output YA1)
00
Not
Allowed
4-74
C029
[AMI] siginal selection
00 (output frequency), 01 (output current),
02 (output torque), 04 (output voltage), 05 (input power), 06 (electronic
thermal overload), 07 (LAD frequency),
09 (motor temperature), 10 (heat sink temperature),
14 (general-purpose output YA2)
00
Not
Allowed
C030
Digital current monitor
reference value
0.20 x "rated current" to 2.00 x "rated current" (A)
(Current with digital current monitor output at 1,440 Hz)
Rated current
Allowed Allowed 4-73
In
tel
lig
en
t
o
u
tp
u
t
ter
mi
n
al
s
C031
Terminal [11] active state
00 (NO) / 01 (NC)
00
Not
Allowed
4-61
C032
Terminal [12] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C033
Terminal [13] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C034
Terminal [14] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C035
Terminal [15] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C036
Alarm relay active state
00 (NO) / 01 (NC)
01
Not
Allowed
Summary of Contents for SJ700D-004L
Page 16: ...Contents Appendix Appendix A 1 Index Index Index 1 ...
Page 44: ...Chapter 2 Installation and Wiring 2 23 Memo ...
Page 70: ...Chapter 3 Operation 3 25 Memo ...
Page 248: ...Chapter 5 Error Codes 5 11 Memo ...
Page 256: ...Chapter6 Maintenance and Inspection 6 7 Memo ...