Chapter 3
Operation
3-14
Example 2:
:
Frequency command source
External potentiometer (Control terminal)
Run command source
RUN/STOP key (Control panel)
(1) I/O connections
(2) Operation
Frequency: Set the frequency command via a potentiometer connected to H/O/L terminal.
Run/Stop: Push the key and to run and stop.
*) Refer to 3.5.2 for changing the frequency command source and 3.5.3 for changing the run
command source.
(3) Parameter settings
Parameter
Details
Setting data
A001
Control circuit terminal block
A002
Digital Operator
H
O
L
Potentiometer
V
R/L1
S/L2
T/L3
R
T
R0
T0
P
PD
N
RB
ELB
U
V
W
M
3-phase induction motor
RUN
STOP/
RESET