Chapter 4
Explanation of Functions
4-144
Register
No.
Function name
Function
code
R/W
Monitoring and setting items
Data
resolution
003Ah Trip monitoring 5 (factor)
d085
R
See the list of inverter trip factors below
-
003Bh Trip monitoring 5 (inverter status)
See the list of inverter trip factors below
-
003Ch Trip monitoring 5 (frequency) (high)
0 to 40000
0.01 [Hz]
003Dh Trip monitoring 5 (frequency (low)
003Eh Trip monitoring 5 (current)
Output current at tripping
0.1 [A]
003Fh Trip monitoring 5 (voltage)
DC input voltage at tripping
1 [V]
0040h Trip monitoring 5 (running time) (high)
Cumulative running time at tripping
1[h]
0041h Trip monitoring 5 (running time) (low)
0042h Trip monitoring 5 (power-on time) (high)
Cumulative power-on time at tripping
1[h]
0043h Trip monitoring 5 (power-on time) (low)
0044h Trip monitoring 6 (factor)
d086
R
See the list of inverter trip factors below
-
0045h Trip monitoring 6 (inverter status)
See the list of inverter trip factors below
-
0046h Trip monitoring 6 (frequency) (high)
0 to 40000
0.01 [Hz]
0047h Trip monitoring 6 (frequency (low)
0048h Trip monitoring 6 (current)
Output current at tripping
0.1 [A]
0049h Trip monitoring 6 (voltage)
DC input voltage at tripping
1 [V]
004Ah Trip monitoring 6 (running time) (high)
Cumulative running time at tripping
1[h]
004Bh Trip monitoring 6 (running time) (low)
004Ch Trip monitoring 6 (power-on time) (high)
Cumulative power-on time at tripping
1[h]
004Dh Trip monitoring 6 (power-on time) (low)
004Eh Programming error monitoring
d090
R
Warning code
-
004Fh to
08FFh
Unused
-
-
Inaccessible
-
0900h Writing to EEPROM
-
W
0000: Motor constant recalculation
0001: Set data storage in EEPROM
Other: Motor constant recalculation and set data
storage in EEPROM
-
0901h Unused
-
-
Inaccessible
-
0902h Write EEPROM mode selection
-
W
0: unavailable writing EEPROM mode
1: available writing EEPROM mode
-
0903h to
1000h
Unused
-
-
Inaccessible
-
Summary of Contents for SJ700D-004L
Page 16: ...Contents Appendix Appendix A 1 Index Index Index 1 ...
Page 44: ...Chapter 2 Installation and Wiring 2 23 Memo ...
Page 70: ...Chapter 3 Operation 3 25 Memo ...
Page 248: ...Chapter 5 Error Codes 5 11 Memo ...
Page 256: ...Chapter6 Maintenance and Inspection 6 7 Memo ...