Chapter 8
List of Data Settings
8-13
Code
Function name
Monitored data or setting
Default
Memo
Change during
RUN operation
Page
FF
FEF FUF
b031
≠
10 b031=10
Co
n
tr
o
l c
o
n
st
an
ts
H001
Auto-tuning Setting
00 (disabling auto-tuning),
01 (auto-tuning without rotation),
02 (auto-tuning with rotation)
00
Not
Not
4-85
H002
Motor data selection, 1st motor
00 (Hitachi standard data), 01 (auto-tuned data),
02 (auto-tuned data [with online auto-tuning function])
00
Not
Not
H202
Motor data selection, 2nd motor
00
Not
Not
H003
Motor capacity, 1st motor
0.20 to 75.00 (kW) <0.20 to 160. (kW) >
Factory setting
Not
Not
H203
Motor capacity, 2nd motor
Factory setting
Not
Not
H004
Motor poles setting, 1st motor
2, 4, 6, 8, 10 (poles)
4
Not
Not
H204
Motor poles setting, 2nd motor
4
Not
Not
H005
Motor speed constant, 1st motor
0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)
1.590
Allowed
Allowed
4-89
4-90
4-97
H205
Motor speed constant, 2nd motor
1.590
Allowed
Allowed
H006
Motor stabilization constant, 1st motor
0. to 255.
100.
Allowed
Allowed
4-79
H206
Motor stabilization constant, 2nd motor
100.
Allowed
Allowed
H306
Motor stabilization constant, 3rd motor
100.
Allowed
Allowed
H020
Motor constant R1, 1st motor
0.001 to 9.999, 10.00 to 65.53 (
)
Factory setting
Not
Not
4-88
4-89
4-90
4-97
H220
Motor constant R1, 2nd motor
Factory setting
Not
Not
H221
Motor constant R2, 1st motor
0.001 to 9.999, 10.00 to 65.53 (
)
Factory setting
Not
Not
H221
Motor constant R2, 2nd motor
Factory setting
Not
Not
H222
Motor constant L, 1st motor
0.01 to 99.99, 100.0 to 655.3 (mH)
Factory setting
Not
Not
H222
Motor constant L, 2nd motor
Factory setting
Not
Not
H223
Motor constant Io
0.01 to 99.99, 100.0 to 655.3 (A)
Factory setting
Not
Not
H223
Motor constant Io, 2nd motor
Factory setting
Not
Not
H224
Motor constant J
0.001 to 9.999, 10.00 to 99.99,
100.0 to 999.9, 1000. to 9999
Factory setting
Not
Not
H224
Motor constant J, 2nd motor
Factory setting
Not
Not
H030
Auto constant R1, 1st motor
0.001 to 9.999, 10.00 to 65.53 (
)
Factory setting
Not
Not
4-85
4-88
4-89
4-90
4-97
H230
Auto constant R1, 2nd motor
Factory setting
Not
Not
H231
Auto constant R2, 1st motor
0.001 to 9.999, 10.00 to 65.53 (
)
Factory setting
Not
Not
H231
Auto constant R2, 2nd motor
Factory setting
Not
Not
H232
Auto constant L, 1st motor
0.01 to 99.99, 100.0 to 655.3 (mH)
Factory setting
Not
Not
H232
Auto constant L, 2nd motor
Factory setting
Not
Not
H233
Auto constant Io, 1st motor
0.01 to 99.99, 100.0 to 655.3 (A)
Factory setting
Not
Not
H233
Auto constant Io, 2nd motor
Factory setting
Not
Not
H234
Auto constant J, 1st motor
0.001 to 9.999, 10.00 to 99.99,
100.0 to 999.9, 1000. to 9999.
Factory setting
Not
Not
H234
Auto constant J, 2nd motor
Factory setting
Not
Not
H050
PI proportional gain for 1st motor
0.0 to 999.9, 1000.
100.0
Allowed
Allowed
4-58
H250
PI proportional gain for 2nd motor
100.0
Allowed
Allowed
H051
PI integral gain for 1st motor
0.0 to 999.9, 1000.
100.0
Allowed
Allowed
H251
PI integral gain for 2nd motor
100.0
Allowed
Allowed
H052
P proportional gain setting for 1st motor
0.01 to 10.00
1.00
Allowed
Allowed
H252
P proportional gain setting for 2nd motor
1.00
Allowed
Allowed
H060
Zero LV lmit for 1st motor
0.0 to 100.0
100.0
Allowed
Allowed
H260
Zero LV lmit for 2nd motor
100.0
Allowed
Allowed
H061
Zero LV starting boost current for 1st motor
0. to 50. (%)
50.
Allowed
Allowed
4-90
H261
Zero LV starting boost current for 2nd motor
50.
Allowed
Allowed
H070
Terminal selection PI proportional gain setting
0.0 to 999.9, 1000.
100.0
Allowed
Allowed
4-58
H071
Terminal selection PI integral gain setting
100.0
Allowed
Allowed
H072
Terminal selection P proportional gain setting
0.00 to 10.00
1.00
Allowed
Allowed
H073
Gain switching time
0. to 9999. (ms)
100.
Allowed
Allowed
(Note)<>indicate the setting range of 75 to 150kW
Summary of Contents for SJ700D-004L
Page 16: ...Contents Appendix Appendix A 1 Index Index Index 1 ...
Page 44: ...Chapter 2 Installation and Wiring 2 23 Memo ...
Page 70: ...Chapter 3 Operation 3 25 Memo ...
Page 248: ...Chapter 5 Error Codes 5 11 Memo ...
Page 256: ...Chapter6 Maintenance and Inspection 6 7 Memo ...