Chapter 8
List of Data Settings
8-15
Code
Function name
Monitored data or setting
Default
Memo
Change during
RUN operation
Page
FF FEF FUF
b031
≠
10 b031=10
Pul
se
co
n
tr
o
l
P055
Pulse-string frequency scale
1.0 to 50.0 (kHz)
25.0
Not
Allowed
4-112
P056
Time constant of pulse-string frequency filter
0.01 to 2.00 (s)
0.10
Not
Allowed
P057
Pulse-string frequency bias
-100. to +100. (%)
0.
Not
Allowed
P058
Pulse-string frequency limit
0. to 100. (%)
100.
Not
Allowed
Ab
so
lu
te
p
o
si
ti
o
n
c
o
n
tr
o
l
P060
Multistage position setting 0
Position setting range reverse side to forward side
(upper 4 digits including “-“)
0
Allowed Allowed
4-106
P061
Multistage position setting 1
Position setting range reverse side to forward side
(upper 4 digits including “-“)
0
Allowed Allowed
P062
Multistage position setting 2
Position setting range reverse side to forward side
(upper 4 digits including “-“)
0
Allowed Allowed
P063
Multistage position setting 3
Position setting range reverse side to forward side
(upper 4 digits including “-“)
0
Allowed Allowed
P064
Multistage position setting 4
Position setting range reverse side to forward side
(upper 4 digits including “-“)
0
Allowed Allowed
P065
Multistage position setting 5
Position setting range reverse side to forward side
(upper 4 digits including “-“)
0
Allowed Allowed
P066
Multistage position setting 6
Position setting range reverse side to forward side
(upper 4 digits including “-“)
0
Allowed Allowed
P067
Multistage position setting 7
Position setting range reverse side to forward side
(upper 4 digits including “-“)
0
Allowed Allowed
P068
Zero-return mode selection
00(Low) / 01 (Hi1) / 00 (Hi2)
00
Allowed Allowed
P069
Zero-return direction selection
00 (FW) / 01 (RV)
00
Allowed Allowed
P070
Low-speed zero-return frequency
0.00 to 10.00 (Hz)
0.00
Allowed Allowed
P071
High-speed zero-return frequency
0.00 to 99.99 / 100.0 to Maximum frequency setting,
1
st
motor (Hz)
0.00
Allowed Allowed
P072
Position range specification (forward)
0 to 268435455 (when P012 = 02)
0 to 1073741823 (when P012 = 03) (upper 4 digits)
2684
(268435455)
Allowed Allowed
P073
Position range specification (reverse)
-268435455 to 0 (when P012 = 02)
-1073741823 to 0 (when P012 = 03) (upper 4 digits)
-268
(-268435455)
Allowed Allowed
P074
Teaching selection
00 (X00) / 01 (X01) / 02 (X02) / 03 (X03) /
04 (X04) / 05 (X05) / 06 (X06) / 07 (X07) /
00
Allowed Allowed
Eas
y
seq
u
en
ce
fu
n
ct
io
n
P100
Easy sequence user parameter U (00)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
4-95
P101
Easy sequence user parameter U (01)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
P102
Easy sequence user parameter U (02)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
P103
Easy sequence user parameter U (03)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
P104
Easy sequence user parameter U (04)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
P105
Easy sequence user parameter U (05)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
P106
Easy sequence user parameter U (06)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
P107
Easy sequence user parameter U (07)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
P108
Easy sequence user parameter U (08)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
P109
Easy sequence user parameter U (09)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
P110
Easy sequence user parameter U (10)
0. to 9999., 1000 to 6553 (10000 to 65535)
0.
Allowed Allowed
(Note) < >indicate the setting range of 75 to 150kW