Chapter 4
Explanation of Functions
4-156
Register
No.
Function name
Function
code
R/W
Monitoring and setting items Data resolution
Data
resolution
1415h
Terminal [11] function
C021
R/W
0 (RUN: running), 1 (FA1: constant-speed reached), 2 (FA2: set
frequency overreached), 3 (OL: overload notice advance signal
(1)), 4 (OD: output deviation for PID control), 5 (AL: alarm
signal), 6 (FA3: set frequency reached), 7 (OTQ: over-torque), 8
(IP: instantaneous power failure), 9 (UV: undervoltage), 10
(TRQ: torque limited), 11 (RNT: operation time over), 12 (ONT:
plug-in time over), 13 (THM: thermal alarm signal), 19 (BRK:
brake release), 20 (BER: braking error), 21 (ZS: 0 Hz detection
signal), 22 (DSE: speed deviation maximum), 23 (POK:
positioning completed), 24 (FA4: set frequency overreached 2),
25 (FA5: set frequency reached 2), 26 (OL2: overload notice
advance signal (2)), 31 (FBV: PID feedback comparison), 32
(NDc: communication line disconnection), 33 (LOG1: logical
operation result 1), 34 (LOG2: logical operation result 2), 35
(LOG3: logical operation result 3), 36 (LOG4: logical operation
result 4), 37 (LOG5: logical operation result 5), 38 (LOG6: logical
operation result 6), 39 (WAC: capacitor life warning), 40 (WAF:
cooling-fan speed drop), 41 (FR: starting contact signal), 42
(OHF: heat sink overheat warning), 43 (LOC: low-current
indication signal), 44 (M01: general-purpose output 1), 45
(M02: general-purpose output 2), 46 (M03: general-purpose
output 3), 47 (M04: general-purpose output 4), 48 (M05:
general-purpose output 5), 49 (M06: general-purpose output
6), 50 (IRDY: inverter ready), 51 (FWR: forward rotation), 52
(RVR: reverse rotation), 53 (MJA: major failur)
54 (WCO: window comparator O), 55 (WCO: window
comparator OI), 56 (WCO: window comparator O2)
(When alarm code output is selected by "C062", functions
"AC0" to "AC2" or "AC0" to "AC3" [ACn: alarm code output] are
forcibly assigned to intelligent output terminals [11] to [13] or
[11] to [14], respectively.)
-
1416h
Terminal [12] function
C022
R/W
-
1417h
Terminal [13] function
C023
R/W
-
1418h
Terminal [14] function
C024
R/W
-
1419h
Terminal [15] function
C025
R/W
-
141Ah
Alarm relay terminal function
C026
R/W
-
141Bh
[FM] siginal selection
C027
R/W
0 (output frequency), 1 (output current), 2 (output torque), 3
(digital output frequency), 4 (output voltage), 5 (input power),
6 (electronic thermal overload), 7 (LAD frequency), 8 (digital
current monitoring), 9 (motor temperature), 10 (heat sink
temperature), 12 (general-purpose output YA0)
-
141Ch
[AM] siginal selection
C028
R/W
0 (output frequency), 1 (output current), 2 (output torque), 4
(output voltage), 5 (input power), 6 (electronic thermal
overload), 7 (LAD frequency), 9 (motor temperature), 10 (heat
sink temperature), 11 (output torque [signed value]), 13
(general-purpose output YA1)
-
141Dh
[AMI] siginal selection
C029
R/W
00 (output frequency), 01 (output current), 02 (output torque),
04 (output voltage), 05 (input power), 06 (electronic thermal
overload), 07 (LAD frequency), 09 (motor temperature), 10
(heat sink temperature), 14 (general-purpose output YA2)
-
141Eh
Digital current monitor reference
value
C030
R/W 200 to 2000
0.1 [%]
141Fh
Terminal [11] active state
C031
R/W 0 (NO), 1 (NC)
-
1420h
Terminal [12] active state
C032
R/W 0 (NO), 1 (NC)
-
1421h
Terminal [13] active state
C033
R/W 0 (NO), 1 (NC)
-
1422h
Terminal [14] active state
C034
R/W 0 (NO), 1 (NC)
-
1423h
Terminal [15] active state
C035
R/W 0 (NO), 1 (NC)
-
1424h
Alarm relay active state
C036
R/W 0 (NO), 1 (NC)
-
1425h
(Reserved)
-
-
Inaccessible
-
1426h
Low-current indication signal
output mode selection
C038
R/W
0 (output during acceleration/deceleration and constant-speed
operation), 1 (output only during constant-speed operation)
-
1427h
Low-current indication signal
detection level
C039
R/W 0 to 2000 <0 to 1800>(CT), 0 to 1500 (VT)
0.1 [%]
1428h
Overload signal output mode
C040
R/W
00 (output during acceleration/deceleration and
constant-speed operation), 01 (output only during
constant-speed operation)
-
1429h
Overload level setting
C041
R/W 0 to 2000 <0 to 1800>(CT), 0 to 1500 (VT)
0.1 [%]
(Note) <>indicate the setting range of 75 to 150kW