Chapter 4
Explanation of Functions
4-152
Register No.
Function name
Function code R/W
Monitoring and setting items Data resolution
Data
resolution
1326h
Reduced voltage start selection
b036
R/W
0 (minimum reduced voltage start time) to 255
(maximum reduced voltage start time)
-
1327h
Function code display restriction
b037
R/W
0 (full display), 1 (function-specific display), 2 (user
setting), 3 (data comparison display), 4 (basicdisplay)
-
1328h
Initial-screen selection
b038
R/W
0 (screen displayed when the STR key was pressed last),
1 to 60 (d001 to d060), 201 (F001)
-
1329h
Automatic user-parameter setting
function enable
b039
R/W 0 (disabling), 1 (enabling)
-
132Ah
Torque limit selection
b040
R/W
00 (quadrant-specific setting), 01 (switching by
terminal), 02 (analog input), 03 (option 1),
04 (option 2)
-
132Bh
Torque limit (1) (forward-driving in
4-quadrant mode)
b041
R/W
0 to 200/255 (no) <0 to 180/255 (no)> (CT)
0 to 150/255 (no) (VT)
1 [%]
132Ch
Torque limit (2)
(reverse-regenerating in 4-quadrant
mode)
b042
R/W
0 to 200/255 (no) <0 to 180/255 (no)> (CT)
0 to 150/255 (no) (VT)
1 [%]
132Dh
Torque limit (3) (reverse-driving in
4-quadrant mode)
b043
R/W
0 to 200/255 (no) <0 to 180/255 (no)> (CT)
0 to 150/255 (no) (VT)
1 [%]
132Eh
Torque limit (4)
(forward-regenerating in
4-quadrant mode)
b044
R/W
0 to 200/255 (no) <0 to 180/255 (no)> (CT)
0 to 150/255 (no) (VT)
1 [%]
132Fh
Torque limit LADSTOP enable
b045
R/W 0 (disabling), 1 (enabling)
-
1330h
Reverse Run protection enable
b046
R/W 0 (disabling), 1 (enabling)
-
1331h to
1332h
(Reserved)
-
-
Inaccessible
-
1333h
Dual rating selection
b049
R/W 0(CT:Constant torque), 1(VT:Variable torque)
-
1334h
Controller deceleration and stop on
power loss
b050
R/W
0 (disabling), 1 (enabling), 2, (nonstop operation at
momentary power failure (no restoration))
3, (nonstop operation at momentary power failure
(restoration to be done))
-
1335h
DC bus voltage trigger level during
power loss
b051
R/W 0 to 10000
0.1 [V]
1336h
Over-voltage threshold during
power loss
b052
R/W 0 to 10000
0.1 [V]
1337h
Deceleration time setting during
power loss (target voltage level)
b053 (high)
R/W
0 to 360000
0.01 [sec.]
1338h
b053 (low)
R/W
1339h
Initial output frequency decrease
during power loss
b054
R/W 0 to 1000
0.01 [Hz]
133Ah
Proportional gain setting for
nonstop operation at momentary
power failure
b055
R/W 0 to 255
0.01
133Bh
Integral time setting for nonstop
operation at momentary power
failure
b056
R/W 0 to 65535
0.001 [sec]
133Ch to
133Eh
(Reserved)
-
-
Inaccessible
-
133Fh
Maximum-limit level of window
comparators O
b060
R/W
0. to 100. (lower limit : b061 + b062 *2) (%)
1 [%]
1340h
Minimum-limit level of window
comparators O
b061
R/W
0. to 100. (lower limit : b060 - b062*2) (%)
1 [%]
1341h
Hysteresis width of window
comparators O
b062
R/W
0. to 10. (lower limit : b061 - b062 / 2) (%)
1 [%]
1342h
Maximum-limit level of window
comparators OI
b063
R/W
0. to 100. (lower limit : b064 + b066 *2) (%)
1 [%]
1343h
Minimum-limit level of window
comparators OI
b064
R/W
0. to 100. (lower limit : b063 - b066 *2) (%)
1 [%]
1344h
Hysteresis width of window
comparators OI
b065
R/W
0. to 10. (lower limit : b063 - b064 / 2) (%)
1 [%]
1345h
Maximum-limit level of window
comparators OI
b066
R/W
-100. to 100. (lower limit : b067 + b068 *2) (%)
1 [%]
1346h
Minimum-limit level of window
comparators O/OI/O2
b067
R/W
-100. to 100. (lower limit : b066 - b068 * 2) (%)
1 [%]
1347h
Hysteresis width of window
comparators O/OI/O2
b068
R/W
0. to 10. (lower limit : b066 - b067 / 2) (%)
1 [%]
1348h
(Reserved)
-
-
Inaccessible
-
1349h
Operation level at O disconnection
b070
R/W
0. to 100. (%) or "no" (ignore)
1 [%]
134Ah
Operation level at OI disconnection
b071
R/W
0. to 100. (%) or "no" (ignore)
1 [%]
134Bh
Operation level at O2 disconnection
b072
R/W
-100. to 100. (%) or "no" (ignore)
1 [%]
134Ch to
1350
(reserved)
-
-
Inaccessible
-
1351h
Cumulative input power data
clearance
b078
R/W Clearance by setting "1"
-
1352h
Cumulative input power display
gain setting
b079
R/W 1 to 1000
1
(Note) <>indicate the setting range of 75 to 150kW
Summary of Contents for SJ700D-004L
Page 16: ...Contents Appendix Appendix A 1 Index Index Index 1 ...
Page 44: ...Chapter 2 Installation and Wiring 2 23 Memo ...
Page 70: ...Chapter 3 Operation 3 25 Memo ...
Page 248: ...Chapter 5 Error Codes 5 11 Memo ...
Page 256: ...Chapter6 Maintenance and Inspection 6 7 Memo ...