Chapter 8
List of Data Settings
8-9
Code
Function name
Monitored data or setting
Default
Memo
Change during
RUN operation
Page
FF FEF FUF
b031
≠
10 b031=10
In
tel
lig
en
t i
n
p
u
t
ter
m
in
al
s
C001
Terminal [1] function (*2)
01 (RV: Reverse RUN), 02 (CF1: Multispeed 1 setting),
03 (CF2: Multispeed 2 setting),
04 (CF3: Multispeed 3 setting),
05 (CF4: Multispeed 4 setting), 06 (JG: Jogging),
07 (DB: external DC braking),
08 (SET: Set 2nd motor data),
09 (2CH: 2-stage acceleration/deceleration),
11 (FRS: free-run stop), 12 (EXT: external trip),
13 (USP: unattended start protection),
14: (CS: commercial power source enable),
15 (SFT: software lock),
16 (AT: analog input voltage/current select),
17 (SET3: 3rd motor control), 18 (RS: reset),
20 (STA: starting by 3-wire input),
21 (STP: stopping by 3-wire input),
22 (F/R: forward/reverse switching by 3-wire input),
23 (PID: PID disable), 24 (PIDC: PID reset),
26 (CAS: control gain setting),
27 (UP: remote control UP function),
28 (DWN: remote control DOWN function),
29 (DWN: remote control data clearing),
31 (OPE: forcible operation), 32 (SF1: multispeed bit 1),
33 (SF2: multispeed bit 2), 34 (SF3: multispeed bit 3),
35 (SF4: multispeed bit 4), 36 (SF5: multispeed bit 5),
37 (SF6: multispeed bit 6), 38 (SF7: multispeed bit 7),
39 (OLR: overload restriction selection),
40 (TL: torque limit enable),
41 (TRQ1: torque limit selection bit 1),
42 (TRQ2: torque limit selection bit 2),
43 (PPI: P/PI mode selection), 44(BOK:braking confirmation),
46 (LAC: LAD cancellation),
47(PCLR:clearance of position deviation)
48(STAT:pulse train position command input enable)
50 (ADD: trigger for frequency addition [A145]),
51 (F-TM: forcible-terminal operation),
52(ATR:permision of torque command input),
53 (KHC: cumulative power clearance),
54(SON:servo-on), 55(FOC:pre-excitation),
56 (MI1: general-purpose input 1),
57 (MI2: general-purpose input 2),
58 (MI3: general-purpose input 3),
59 (MI4: general-purpose input 4),
60 (MI5: general-purpose input 5),
61 (MI6: general-purpose input 6),
62 (MI7: general-purpose input 7),
63 (MI8: general-purpose input 8),
64(EMR: Emergency stop signal),
65 (AHD: analog command holding),
66(CP1:multi stage position settings selection 1),
67(CP2:multi stage position settings selection 2),
68(CP3:multi stage position settings selection 3),
69(ORL:Zero-return limit function),
70(ORG:Zero-return trigger function),
71(FOT:forward drive stop),72(ROT:reverce drive stop),
73(SPD:speed/position switching),
74 (PCNT: pulse counter), 75 (PCC: pulse counter clear),
82(PRG:EzSQ program-run terminal),
no (NO: no assignment)
18
(*2)
Not
Allowed
4-46
C002
Terminal [2] function
16
Not
Allowed
C003
Terminal [3] function (*2)
06
(*2)
Not
Allowed
C004
Terminal [4] function
11
Not
Allowed
C005
Terminal [5] function
09
Not
Allowed
C006
Terminal [6] function
03 03 13
Not
Allowed
C007
Terminal [7] function
02
Not
Allowed
C008
Terminal [8] function
01
Not
Allowed
C011
Terminal [1] active state
00 (NO) / 01 (NC)
00
Not
Allowed
4-47
C012
Terminal [2] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C013
Terminal [3] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C014
Terminal [4] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C015
Terminal [5] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C016
Terminal [6] active state
00 (NO) / 01 (NC)
00 00 01
Not
Allowed
C017
Terminal [7] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C018
Terminal [8] active state
00 (NO) / 01 (NC)
00
Not
Allowed
C019
Terminal [FW] active state
00 (NO) / 01 (NC)
00
Not
Allowed
*2 When the emergency stop function is enabled (SW1 = ON), "18" (RS) and "64" (EMR) are forcibly written to parameters "C001" and "C003", respectively. (You
cannot arbitrarily write "64" to "C001".) If the SW1 signal is turned off and then turned on, "no" (no assignment) is set in parameter "C003".
Summary of Contents for SJ700D-004L
Page 16: ...Contents Appendix Appendix A 1 Index Index Index 1 ...
Page 44: ...Chapter 2 Installation and Wiring 2 23 Memo ...
Page 70: ...Chapter 3 Operation 3 25 Memo ...
Page 248: ...Chapter 5 Error Codes 5 11 Memo ...
Page 256: ...Chapter6 Maintenance and Inspection 6 7 Memo ...