Chapter 8
List of Data Settings
8-3
8.4 Extended Function Mode
Code
Function name
Monitored data or setting
Default
Memo
Change during
RUN operation Page
FF FEF FUF
b031
≠
10 b031=10
B
as
ic
s
et
ti
ng
s
A001 Frequency source setting
00 (keypad potentiometer) (*1), 01 (control circuit terminal block),
02 (digital operator), 03 (RS485), 04 (option 1), 05 (option 2),
06 (pulse-string input), 07 (easy sequence),
10 (operation function result)
02
01
01
Not
Not
4-8
A002 Run command source setting
01 (control circuit terminal block), 02 (digital operator), 03 (RS485),
04 (option 1), 05 (option 2)
02
01
01
Not
Not
4-8
A003 Base frequency setting
30. to "Maximum frequency " (Hz)
60.
50.
60.
Not
Not
4-11
A203 Base frequency setting, 2nd motor
30. to "Maximum frequency, 2nd motor" (Hz)
60.
50.
60.
Not
Not
A303 Base frequency setting, 3rd motor
30. to "Maximum frequency, 3rd motor" (Hz)
60.
50.
60.
Not
Not
A004 Maximum frequency setting
"Base frequency setting " to 400. (Hz)
60.
50.
60.
Not
Not
4-11
A204 Maximum frequency setting, 2nd motor
"Base frequency setting, 2nd motor " to 400. (Hz)
60.
50.
60.
Not
Not
A304 Maximum frequency setting, 3rd motor
"Base frequency setting, 3rd motor " to 400. (Hz)
60.
50.
60.
Not
Not
An
al
o
g
in
p
u
t
an
d
o
th
e
rs
A005 [AT] selection
00 (switching between O and OI terminals),
01 (switching between O and O2 terminals),
02 (switching between O terminal and keypad potentiometer) (*1),
03 (switching between OI terminal and keypad potentiometer) (*1),
04 (switching between O2 and keypad potentiometer) (*1)
00
Not
Not
4-12
A006 [O2] selection
00 (single),
01 (auxiliary frequency input via O and OI terminals) (nonreversible),
02 (auxiliary frequency input via O and OI terminals) (reversible),
03 disabling O2 terminal)
03
Not
Not
A011 [O]-[L] input active range start frequency
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
Not
Allowed
4-14
A012 [O]-[L] input active range end frequency
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00
Not
Allowed
A013 [O]-[L] input active range start voltage
0. to "[O]-[L] input active range end voltage" (%)
0.
Not
Allowed
A014 [O]-[L] input active range end voltage
"[O]-[L] input active range start voltage" to 100. (%)
100.
Not
Allowed
A015
[O]-[L] input active range start frequency
selection
00 (external start frequency), 01 (0 Hz)
01
Not
Allowed
A016 External frequency filter time const.
1. to 30. or 31. (500 ms filter ±0.1 Hz with hysteresis)
31.
Not
Allowed 4-15
A017 Easy sequence function selection
00 (disabling), 01 (PRG terminal running), 02(always runnning)
00
Not
Not
4-95
M
u
lt
is
p
ee
d
o
p
er
at
io
n
an
d
jo
gg
in
g
A019 Multispeed operation selection
00 (binary: 16 speeds selectable with 4 terminals),
01 (bit: 8 speeds selectable with 7 terminals)
00
Not
Not
4-47
A020 Multispeed frequency setting
0.0 or “start frequency” to “maximum frequency” (Hz)
0.00
Allowed Allowed
A220 Multispeed frequency setting, 2nd motor
0.0 or “start frequency” to “maximum frequency, 2nd motor” (Hz)
0.00
Allowed Allowed
A320 Multispeed frequency setting, 3rd motor
0.0 or “start frequency” to “maximum frequency, 3rd motor” (Hz)
0.00
Allowed Allowed
A021 Multispeed 1 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A022 Multispeed 2 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A023 Multispeed 3 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A024 Multispeed 4 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A025 Multispeed 5 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A026 Multispeed 6 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A027 Multispeed 7 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A028 Multispeed 8 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A029 Multispeed 9 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A030 Multispeed 10 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A031 Multispeed 11 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A032 Multispeed 12 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A033 Multispeed 13 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A034 Multispeed 14 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A035 Multispeed 15 setting
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.00
Allowed Allowed
A038 Jog frequency setting
"Start frequency" to 9.99 (Hz)
1.00
Allowed Allowed
4-49
A039 Jog stop mode
00 (free-running after jogging stops [disabled during operation]),
01 (deceleration and stop after jogging stops [disabled during operation]),
02 (DC braking after jogging stops [disabled during operation]),
03 (free-running after jogging stops [enabled during operation]),
04 (deceleration and stop after jogging stops [enabled during operation]),
05 (DC braking after jogging stops [enabled during operation])
00
Not
Allowed
*1 This setting is valid only when the OPE-SR is connected.