Chapter 4
Explanation of Functions
4-142
Coil No.
Item
R/W
Setting
0035h
LOG2 (logical operation result 2)
R
1: ON, 0: OFF
0036h
LOG3 (logical operation result 3)
R
1: ON, 0: OFF
0037h
LOG4 (logical operation result 4)
R
1: ON, 0: OFF
0038h
LOG5 (logical operation result 5)
R
1: ON, 0: OFF
0039h
LOG6 (logical operation result 6)
R
1: ON, 0: OFF
003Ah
WAC (capacitor life warning)
R
1: ON, 0: OFF
003Bh
WAF (cooling-fan speed drop)
R
1: ON, 0: OFF
003Ch
FR (starting contact signal)
R
1: ON, 0: OFF
003Dh
OHF (heat sink overheat warning)
R
1: ON, 0: OFF
003Eh
LOC (low-current indication signal)
R
1: ON, 0: OFF
003Fh
M01 (general output 1)
R
1: ON, 0: OFF
0040h
M02 (general output 2)
R
1: ON, 0: OFF
0041h
M03 (general output 3)
R
1: ON, 0: OFF
0042h
M04 (general output 4)
R
1: ON, 0: OFF
0043h
M05 (general output 5)
R
1: ON, 0: OFF
0044h
M06 (general output 6)
R
1: ON, 0: OFF
0045h
IRDY (inverter ready)
R
1: ON, 0: OFF
0046h
FWR (forward rotation)
R
1: ON, 0: OFF
0047h
RVR (reverse rotation)
R
1: ON, 0: OFF
0048h
MJA (major failure)
R
1: ON, 0: OFF
0049h
Data writing in progress
R
1: Writing in progress, 0: Normal status
004Ah
CRC error
R
1: Error detected, 0: No error (*2)
004Bh
Overrun
R
1: Error detected, 0: No error (*2)
004Ch
Framing error
R
1: Error detected, 0: No error (*2)
004Dh
Parity error
R
1: Error detected, 0: No error (*2)
004Eh
Sum check error
R
1: Error detected, 0: No error (*2)
004Fh
(reserved)
0050h
WCO (window comparator O)
R
1: ON, 0:FF
0051h
WCO (window comparator OI)
R
1: ON, 0:FF
0052h
WCO (window comparator O2)
R
1: ON, 0:FF
*1 Normally, this coil is turned on when the corresponding intelligent input terminal on the control circuit terminal
block is turned on or the coil itself is set to on. In this regard, the operation of the intelligent input terminal has
priority over the operation of the coil. If disconnection of the communication train has disabled the master system
from turning off the coil, turn the corresponding intelligent input terminal on the control circuit block on and off.
This operation turns off the coil.
*2 Communication error data is retained until an error reset command is input. (The data can be reset during the
inverter operation.)
Summary of Contents for SJ700D-004L
Page 16: ...Contents Appendix Appendix A 1 Index Index Index 1 ...
Page 44: ...Chapter 2 Installation and Wiring 2 23 Memo ...
Page 70: ...Chapter 3 Operation 3 25 Memo ...
Page 248: ...Chapter 5 Error Codes 5 11 Memo ...
Page 256: ...Chapter6 Maintenance and Inspection 6 7 Memo ...