73
Configuring Module-Specific Settings
Configuring Model 8971 Current Unit settings
> [Channel] > [8971]
4
1, 2
3
1
Confirm the output rate displayed in the
[Mode]
area.
The instrument automatically recognizes a current sensor connected to Model 8971 Current Unit and displays
it as follows:
20A/2V
When one of the following current sensors is connected: Model 9272-10 (20 A range)
and Model CT6841.
200A/2V
When one of the following current sensors is connected: Model 9272-10 (200 A range),
Model CT6843, and CT6863.
50A/2V
When Model CT6862 AC/DC Current Sensor is connected
500A/2V
When one of the following current sensors is connected: Models 9709, CT6844,
CT6845, CT6846*, and CT6865*.
None
When no current sensor is connected.
IMPORTANT
*: When Model CT6846 or Model CT6865 connects to Model 8971 Current Unit via Model 9318
Conversion Cable, the instrument recognizes the sensor as a 500 A AC/DC sensor. Set the
conversion ratio at 2.00 in the scaling setting.
2
In the
[Mode]
area, tap the
[DC]
or
[RMS]
to choose a measurement mode.
DC
For current measurement
RMS
For RMS measurement
3
(When you have changed the measurement mode) Tap
[Zero adjust]
.
The instrument performs zero-adjustment. Execute zero-adjustment without any input.
Advanced Functions
HIOKI MR6000A966-03
Summary of Contents for Memory HiCorder MR6000
Page 2: ...HIOKI MR6000A966 03...
Page 56: ...50 Displaying Measured Values HIOKI MR6000A966 03...
Page 152: ...146 Triggering the Instrument Using CAN Signals CAN Trigger HIOKI MR6000A966 03...
Page 194: ...188 Numerical Calculation Types and Descriptions HIOKI MR6000A966 03...
Page 266: ...260 Configuring the Display Settings HIOKI MR6000A966 03...
Page 391: ...HIOKI MR6000A966 03...
Page 392: ...HIOKI MR6000A966 03...