3.3.1 Access to Confi guration
1 As shown in fi gure 3.3.1a, once the recorder has initialised, touch the current access level key
2 Touch the ‘Logged out’ fi eld and then touch ‘Engineer’ from the resulting picklist.
3 Touch the blank Password area to call the keyboard display (see fi gure 3.3.1b).
4 Touch <Numeric><1><0><0><OK> to enter the password ‘100’. The screen reverts to the ‘Home’
page.
5 Operation of the Root key followed by a touch on the Operator key calls the top level page allowing
access to the
Archive
,
Save/Restore
,
Confi g
,
Security
,
Network
and
System
areas described in
sec-
tion 4
below.
Figure 3.3.1a Access to confi guration
Notes:
1. For units which have the Auditor 21CFR11 Option enabled, the default Operator password is
‘100’. Otherwise no password is required for default Operator level access. In either case the
Operator access level password can be edited in ‘Security’ confi guration. (
Section 4.4.1
.)
2. The login screen, above, can also be called by operating the Root menu, then ‘Operator’ then
‘Security’, then ‘Login’. In such a case, the screen reverts to the ‘Operator’ page rather than
returning to the home page once login has been achieved.
3. Figure 3.3.1a shows ‘Login by user list’ which is the default method. If either Auditor option
and/or the Security management option is enabled, an alternative procedure is possible where
each user has to enter a name and associated password - i.e. there is no list of users/access
levels to choose from. See
section 4.4.2
(Management) for details.
4. For Active Directory users, a password expiry warning message (below) pops up on log-in,
stating how many days remain before the password expires (confi gured at the Active Directory
server).
Touch Current
access level key
Group name
11:52:59
05/04/05
11:52:04
05/04/05
11:49:24
05/04/05
11:46:44
05/04/05
Logged out
Login
Select the required access level and enter the password if
required.
Close
User
Logged out
Operator
Engineer
Service
Logged out
Touch 'logged out'
area...
...then touch access
level required.
Touch the password window when it appears, and enter the password.
The Engineer level password is '100' when the unit is despatched from
the factory. Passwords can be edited in 'Security' as described in sec-
tion 4.4.1.
The screen reverts to the home page, with the new access level dis-
played in the 'Current access level' key
0.0000
1.0000
Channel 1
0.0237V
0.2000
0.4000
0.6000
0.8000
1
2
3
Warning
Fred password expires in 2 days
Ok